Results for DSG2546_X_001_D_H2


The information on this page was generated on Tue Jul 7 06:21:02 2026 (America/Los_Angeles).
You may click the button below to manually regenerate the content.

Basic Information for DSG2546_X_001_D_H2


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier UCSC-X-1103
Serial Number 20USBHX2006286
Batch PRODUCTION_UCSC
Assembled True
Completed False
Current Location SCIPP, UC Santa Cruz
Manufacture ID DSG2546_X_001_D_H2
User SCIPP Module Institute Account

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2026-05-22T18:10:29.764Z
HCC Chip HCCSTARV1 2026-05-27T22:05:25.607Z
ABC Chip ABCSTARV1 2026-05-27T22:05:27.240Z
ABC Chip ABCSTARV1 2026-05-27T22:05:28.846Z
ABC Chip ABCSTARV1 2026-05-27T22:05:30.474Z
ABC Chip ABCSTARV1 2026-05-27T22:05:32.070Z
ABC Chip ABCSTARV1 2026-05-27T22:05:33.700Z
ABC Chip ABCSTARV1 2026-05-27T22:05:35.291Z
ABC Chip ABCSTARV1 2026-05-27T22:05:36.888Z
ABC Chip ABCSTARV1 2026-05-27T22:05:38.464Z
ABC Chip ABCSTARV1 2026-05-27T22:05:40.062Z
ABC Chip ABCSTARV1 2026-05-27T22:05:41.657Z
Hybrid Interposer 2026-05-22T18:10:26.428Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel
Module 2026-06-26T20:52:10.141Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2026-05-22T18:46:49.374Z
Visual Inspection 2026-05-26T23:02:38.000Z
ASIC Metrology 2026-05-22T21:15:32.709Z
Wire bonding 2026-05-26T23:02:38.000Z
Pedestal Trim Burn In 2026-05-28T18:49:25.000Z
Strobe Delay Burn In 2026-05-28T18:49:49.000Z
Response Curve Burn In 2026-05-28T18:51:19.000Z
Noise Occupancy Burn In 2026-05-28T18:57:19.000Z
Pedestal Trim TC 2026-07-02T13:34:42.000Z
Strobe Delay TC 2026-07-02T13:34:54.000Z
Response Curve TC 2026-07-02T13:36:29.000Z
Noise Occupancy TC 2026-07-02T13:45:04.000Z
Open Channel Search TC 2026-07-02T13:47:48.000Z

Glue weight for DSG2546_X_001_D_H2


Shown below are results for the glue weight measurements

IService::UPLOADDB                         INFO                Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB                    INFO                Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component DSG2546_X_001_D_H2
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2546_X_001_D_H2/GlueWeightHybridASIC_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed 20USBHX2006286_image.jpg...
IService::install                          INFO                Installed DB_COMMENTS.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed DSG2546_X_001_D_H2.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!

MetadataValue
Component type
Operator LM,AS
Date 2026-05-22T18:46:49.374+00:00
Program ASIC_X_PPB.src
FieldWeight/Volume
Assummed density of glue 1.077
Total volume of ASIC glue [uL] 38.168
Volume per glue dot [nL] 734.005
Weight of glue under ASICs [mg] 41.100
Weights of bare hybrid [g] 2.531
Weights of stuffed hybrid [g] 2.572

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               485.386250 +/- 5.449000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               86.343875 +/- 9.896843 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             399.042375
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 99.042375 +/- 12.354720 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 400.042375 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               479.784500 +/- 2.460000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               95.724333 +/- 5.703333 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             384.060167
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.060167 +/- 7.973682 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.060167 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               470.351750 +/- 5.914500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               86.659222 +/- 5.307167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             383.692528
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.692528 +/- 9.388681 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.692528 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               467.851250 +/- 2.196000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               81.466778 +/- 6.295500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             386.384472
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 86.384472 +/- 8.334011 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 387.384472 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               463.557500 +/- 3.063500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               84.731556 +/- 6.764500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             378.825944
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 78.825944 +/- 8.952290 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 379.825944 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               459.850750 +/- 2.252500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               72.215889 +/- 5.502167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             387.634861
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.634861 +/- 7.768371 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.634861 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               458.127750 +/- 1.384250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               66.560222 +/- 8.484167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             391.567528
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 91.567528 +/- 9.944709 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 392.567528 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               457.283250 +/- 1.398000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               69.099000 +/- 6.752667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             388.184250
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 88.184250 +/- 8.517800 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 389.184250 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               458.181000 +/- 1.861750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               60.373222 +/- 7.665333 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             397.807778
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 97.807778 +/- 9.339349 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 398.807778 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               461.990000 +/- 1.762000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               52.326625 +/- 7.757315 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             409.663375
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 109.663375 +/- 9.395775 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 410.663375 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               469.583750 +/- 0.995000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               60.044750 +/- 1.229128 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             409.539000
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 109.539000 +/- 5.244119 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 410.539000 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 943.219250, chip thickness 300.000000 and glue 99.042375, giving hybrid 544.176875 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 937.103171, chip thickness 300.000000 and glue 84.060167, giving hybrid 553.043004 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.172768, chip thickness 300.000000 and glue 83.692528, giving hybrid 547.480240 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.863258, chip thickness 300.000000 and glue 86.384472, giving hybrid 545.478786 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.351375, chip thickness 300.000000 and glue 78.825944, giving hybrid 552.525430 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.102564, chip thickness 300.000000 and glue 87.634861, giving hybrid 543.467703 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.298882, chip thickness 300.000000 and glue 91.567528, giving hybrid 539.731354 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 930.788321, chip thickness 300.000000 and glue 88.184250, giving hybrid 542.604071 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 931.799001, chip thickness 300.000000 and glue 97.807778, giving hybrid 533.991223 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 936.992911, chip thickness 300.000000 and glue 109.663375, giving hybrid 527.329536 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 938.762750, chip thickness 300.000000 and glue 109.539000, giving hybrid 529.223750 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H2/1//Data__DSG2546_X_001_D_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H2/1//Results__DSG2546_X_001_D_H2.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H2/1//Data__DSG2546_X_001_D_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H2/1//Results__DSG2546_X_001_D_H2.txt
IService::log                              INFO                Logging status 0111 for component DSG2546_X_001_D_H2
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2546_X_001_D_H2/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__DSG2546_X_001_D_H2.txt...
IService::install                          INFO                Installed Results__DSG2546_X_001_D_H2.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed DSG2546_X_001_D_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H3-1.config
IService::next                             INFO                Scheduling DSG2546-001-D0-2-3-4.txt file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2546_X_001_D_H3/1/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0010015
Measurement::addPoint                      ERROR               Unknown type ?! Ignoring!
MetadataValue
Component type X
Operator LM
Date 2026-05-22T21:15:32.709+00:00
Program version MetrologyHybrid_PROD_X_v2_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thin_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Wirebonding for DSG2546_X_001_D_H2


Wirebonding summaries will be given below

WireBondSvc::run                           INFO                Loading group FAILED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run                           INFO                Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB                         INFO                Working on test code WIRE_BONDING
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component DSG2546_X_001_D_H2
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2546_X_001_D_H2/HybridBonding_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed DSG2546_X_001_D_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//HybridBonding_v1//DSG2546_X_001_D_H3-1.config
IService::next                             INFO                Scheduling HybridBonding_DSG2546_X_001_D_H3-1.json file to run...
IService::next                             INFO                Writing results to /home/data/output//HybridBonding_v1//DSG2546_X_001_D_H3/1/
MetadataValue
Date 2026-05-26T23:02:38.000+00:00
Operator LM
Bonder hk1
Version v1
Bond numberTypeComment

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files DSG2546_X_001_D_H2/20USBHX2006286
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files DSG2546_X_001_D_H2/20USBHX2006286
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_powerCycleTest_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2006286_20260527_21_NO_BURNIN.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//DSG2546_X_001_D_H2_GAIN_TEST.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 0111 for component DSG2546_X_001_D_H2
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2546_X_001_D_H2/BurnInHybrids_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2006286_20260527_21_PEDESTAL_TRIM_BURNIN.json...
IService::install                          INFO                Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2006286_20260527_21_STROBE_DELAY_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2006286_20260527_21_RESPONSE_CURVE_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2006286_20260527_21_3PG_BURNIN.json...
IService::install                          INFO                Installed DB_READY_NO_BURNIN_SN20USBHX2006286_20260527_21_NO_BURNIN.json...
IService::install                          INFO                Installed DSG2546_X_001_D_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//BurnInHybrids_PROD_v2//DSG2546_X_001_D_H3-1.config
IService::next                             INFO                Scheduling Burnin_Panel_61_62_66_May27_2026 file to run...
IService::next                             INFO                Writing results to /home/data/output//BurnInHybrids_PROD_v2//DSG2546_X_001_D_H3/1/
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for DSG2546_X_001_D_H2
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0010015

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.