The information on this page was generated on Sun Aug 30 06:25:17 2026 (America/Los_Angeles). You may click the button below to manually regenerate the content.
Basic Information for DSG2608_X_030_C_H2
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H2
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H2/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2008031_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_030_C_H2.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
LM, AS
Date
2026-07-17T22:03:49.499+00:00
Program
ASIC_X_PPB.src
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.026
Volume per glue dot [nL]
769.723
Weight of glue under ASICs [mg]
43.100
Weights of bare hybrid [g]
2.521
Weights of stuffed hybrid [g]
2.564
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 456.831750 +/- 5.563500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 70.403500 +/- 8.890100 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 386.428250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 86.428250 +/- 11.618365 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 387.428250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 451.383500 +/- 2.504250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 70.924444 +/- 7.250667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 380.459056
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 80.459056 +/- 9.156606 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 381.459056 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 442.978750 +/- 2.932250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 59.772333 +/- 6.677500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.206417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.206417 +/- 8.842347 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.206417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 438.945250 +/- 1.373250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 67.274000 +/- 7.856167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 371.671250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 71.671250 +/- 9.413032 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 372.671250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 435.611750 +/- 1.055250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 60.724444 +/- 7.080667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 374.887306
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 74.887306 +/- 8.732090 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 375.887306 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 432.585500 +/- 0.868000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 54.640222 +/- 8.881167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 377.945278
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 77.945278 +/- 10.228810 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 378.945278 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 431.692000 +/- 0.682750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 64.606333 +/- 8.432500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 367.085667
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 67.085667 +/- 9.827167 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 368.085667 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 431.086000 +/- 1.234500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 54.094667 +/- 8.070500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 376.991333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.991333 +/- 9.573764 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.991333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 433.535750 +/- 2.062000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 49.686667 +/- 7.937167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.849083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.849083 +/- 9.604710 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.849083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 440.141750 +/- 1.911750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 54.262750 +/- 7.920833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 385.879000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 85.879000 +/- 9.560041 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 386.879000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 444.148000 +/- 1.316000 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 63.975125 +/- 3.297416 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 380.172875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 80.172875 +/- 6.132276 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 381.172875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 942.547000, chip thickness 300.000000 and glue 86.428250, giving hybrid 556.118750 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.409565, chip thickness 300.000000 and glue 80.459056, giving hybrid 554.950510 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.122820, chip thickness 300.000000 and glue 83.206417, giving hybrid 545.916403 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 926.907799, chip thickness 300.000000 and glue 71.671250, giving hybrid 555.236549 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 926.000507, chip thickness 300.000000 and glue 74.887306, giving hybrid 551.113201 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 925.038342, chip thickness 300.000000 and glue 77.945278, giving hybrid 547.093065 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 924.697417, chip thickness 300.000000 and glue 67.085667, giving hybrid 557.611750 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 923.052162, chip thickness 300.000000 and glue 76.991333, giving hybrid 546.060829 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 924.245831, chip thickness 300.000000 and glue 83.849083, giving hybrid 540.396748 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 930.870919, chip thickness 300.000000 and glue 85.879000, giving hybrid 544.991919 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.633750, chip thickness 300.000000 and glue 80.172875, giving hybrid 549.460875 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H2/2//Data__DSG2608_X_030_C_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H2/2//Results__DSG2608_X_030_C_H2.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H2/2//Data__DSG2608_X_030_C_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H2/2//Results__DSG2608_X_030_C_H2.txt
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H2
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H2/MetrologyHybrid_PROD_X_v2_interposer-2/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__DSG2608_X_030_C_H2.txt...
IService::install INFO Installed Results__DSG2608_X_030_C_H2.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed DSG2608_X_030_C_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3-1.config
IService::next INFO Scheduling DSG2608-030-C1-2-3-4-5-6.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0011969
Measurement::addPoint ERROR Unknown type ?! Ignoring!
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for DSG2608_X_030_C_H2
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H2
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H2/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_030_C_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//DSG2608_X_030_C_H3-1.config
IService::next INFO Scheduling HybridBonding_DSG2608_X_030_C_H3-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//DSG2608_X_030_C_H3/1/
Metadata
Value
Date
2026-07-21T22:33:38.427+00:00
Operator
AD, AS
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files DSG2608_X_030_C_H2/20USBHX2008031
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files DSG2608_X_030_C_H2/20USBHX2008031
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_powerCycleTest_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008031_20260722_10_STROBE_DELAY_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H2_GAIN_TEST.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H2
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H2/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008031_20260722_10_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008031_20260722_10_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008031_20260722_10_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008031_20260722_10_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2008031_20260722_10_NO_BURNIN.json...
IService::install INFO Installed DSG2608_X_030_C_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H3-1.config
IService::next INFO Scheduling Burnin_Panel_56_July22_2026 file to run...
IService::next INFO Writing results to /home/data/output//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H3/1/
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for DSG2608_X_030_C_H2
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0011969
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362267
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362266
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362265
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362264
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362263
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362262
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362261
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362260
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362259
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362258
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.