The information on this page was generated on Sun Aug 30 06:25:24 2026 (America/Los_Angeles). You may click the button below to manually regenerate the content.
Basic Information for DSG2608_X_030_C_H3
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H3
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H3/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2008032_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_030_C_H3.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
LM, AS
Date
2026-07-17T22:10:19.452+00:00
Program
ASIC_X_PPB.src
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
39.468
Volume per glue dot [nL]
759.008
Weight of glue under ASICs [mg]
42.500
Weights of bare hybrid [g]
2.546
Weights of stuffed hybrid [g]
2.588
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 468.717250 +/- 5.778500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 84.252125 +/- 9.809869 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 384.465125
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.465125 +/- 12.434814 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.465125 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 463.896500 +/- 2.317000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 96.436222 +/- 6.591167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 367.460278
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 67.460278 +/- 8.591389 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 368.460278 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 456.376750 +/- 2.735750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 80.244333 +/- 6.064000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 376.132417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.132417 +/- 8.322044 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.132417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 452.200250 +/- 1.126500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 79.199889 +/- 8.523333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 373.000361
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 73.000361 +/- 9.945663 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 374.000361 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 449.036000 +/- 0.756750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 81.691667 +/- 7.454167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 367.344333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 67.344333 +/- 9.007623 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 368.344333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 446.840750 +/- 0.499750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 70.144889 +/- 6.298167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 376.695861
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.695861 +/- 8.057087 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.695861 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 444.648250 +/- 0.901250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 68.747889 +/- 8.846500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 375.900361
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 75.900361 +/- 10.201608 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 376.900361 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 444.247750 +/- 0.582750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 72.088111 +/- 7.886667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 372.159639
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 72.159639 +/- 9.356234 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 373.159639 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 446.944750 +/- 1.532750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 61.026333 +/- 5.854667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 385.918417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 85.918417 +/- 7.850251 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 386.918417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 452.184500 +/- 1.932250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 58.499625 +/- 9.432097 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 393.684875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 93.684875 +/- 10.848873 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 394.684875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 456.434000 +/- 1.648750 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 66.357875 +/- 3.885552 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 390.076125
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.076125 +/- 6.543385 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.076125 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 942.942250, chip thickness 300.000000 and glue 84.465125, giving hybrid 558.477125 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 936.552207, chip thickness 300.000000 and glue 67.460278, giving hybrid 569.091929 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.635252, chip thickness 300.000000 and glue 76.132417, giving hybrid 555.502835 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.775843, chip thickness 300.000000 and glue 73.000361, giving hybrid 556.775482 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.527586, chip thickness 300.000000 and glue 67.344333, giving hybrid 562.183253 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.898440, chip thickness 300.000000 and glue 76.695861, giving hybrid 553.202579 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 928.747856, chip thickness 300.000000 and glue 75.900361, giving hybrid 552.847495 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 927.781816, chip thickness 300.000000 and glue 72.159639, giving hybrid 555.622177 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.715643, chip thickness 300.000000 and glue 85.918417, giving hybrid 543.797226 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.447690, chip thickness 300.000000 and glue 93.684875, giving hybrid 541.762815 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.590000, chip thickness 300.000000 and glue 90.076125, giving hybrid 544.513875 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3/1//Data__DSG2608_X_030_C_H3.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3/1//Results__DSG2608_X_030_C_H3.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3/1//Data__DSG2608_X_030_C_H3.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H3/1//Results__DSG2608_X_030_C_H3.txt
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H3
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H3/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__DSG2608_X_030_C_H3.txt...
IService::install INFO Installed Results__DSG2608_X_030_C_H3.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed DSG2608_X_030_C_H3.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H4-3.config
IService::next INFO Scheduling DSG2608-030-C1-2-3-4-5-6.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_030_C_H4/3/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0011970
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for DSG2608_X_030_C_H3
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H3
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H3/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_030_C_H3.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//DSG2608_X_030_C_H4-1.config
IService::next INFO Scheduling HybridBonding_DSG2608_X_030_C_H4-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//DSG2608_X_030_C_H4/1/
Metadata
Value
Date
2026-07-21T22:33:38.440+00:00
Operator
AD, AS
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files DSG2608_X_030_C_H3/20USBHX2008032
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files DSG2608_X_030_C_H3/20USBHX2008032
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008032_20260722_10_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008032_20260722_10_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008032_20260722_10_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008032_20260722_10_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008032_20260722_10_3PG_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H3_GAIN_TEST.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component DSG2608_X_030_C_H3
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_030_C_H3/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008032_20260722_10_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008032_20260722_10_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008032_20260722_10_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008032_20260722_10_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2008032_20260722_10_NO_BURNIN.json...
IService::install INFO Installed DSG2608_X_030_C_H3.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H4-1.config
IService::next INFO Scheduling Burnin_Panel_56_July22_2026 file to run...
IService::next INFO Writing results to /home/data/output//BurnInHybrids_PROD_v2//DSG2608_X_030_C_H4/1/
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for DSG2608_X_030_C_H3
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0011970
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362279
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362277
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362276
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362275
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362274
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362273
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362272
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362271
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362269
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1362268
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.