The information on this page was generated on Sun Aug 30 06:39:54 2026 (America/Los_Angeles). You may click the button below to manually regenerate the content.
Basic Information for DSG2608_X_035_A_H6
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_035_A_H6
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_035_A_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2008461_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_035_A_H6.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
AS, LM
Date
2026-08-14T23:36:14.868+00:00
Program
ASIC_X_PPB.src
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.769
Volume per glue dot [nL]
784.010
Weight of glue under ASICs [mg]
43.900
Weights of bare hybrid [g]
2.501
Weights of stuffed hybrid [g]
2.545
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 457.729000 +/- 7.177000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 75.603250 +/- 11.227088 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 382.125750
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 82.125750 +/- 14.232246 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 383.125750 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 456.311000 +/- 2.956000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 71.692667 +/- 7.969333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 384.618333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.618333 +/- 9.861451 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.618333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 448.862000 +/- 1.492000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 63.664444 +/- 7.663667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 385.197556
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 85.197556 +/- 9.271346 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 386.197556 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 442.599250 +/- 2.709500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 72.432667 +/- 8.607500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 370.166583
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 70.166583 +/- 10.316513 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 371.166583 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 440.815000 +/- 1.381250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 66.801111 +/- 8.863333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 374.013889
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 74.013889 +/- 10.269690 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 375.013889 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 438.279750 +/- 1.709000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 61.975889 +/- 8.056167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 376.303861
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.303861 +/- 9.634444 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.303861 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 434.426750 +/- 2.589250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 65.867111 +/- 8.323000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 368.559639
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 68.559639 +/- 10.048709 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 369.559639 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 435.420750 +/- 2.195000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 65.225333 +/- 7.334333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 370.195417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 70.195417 +/- 9.143876 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 371.195417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 441.234250 +/- 1.652000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 64.702000 +/- 8.069167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 376.532250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.532250 +/- 9.635380 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.532250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 447.684000 +/- 1.592500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 56.775750 +/- 9.947225 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 390.908250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.908250 +/- 11.246481 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.908250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 453.025750 +/- 1.876250 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 81.585375 +/- 3.988436 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 371.440375
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 71.440375 +/- 6.665428 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 372.440375 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 940.513250, chip thickness 300.000000 and glue 82.125750, giving hybrid 558.387500 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.275611, chip thickness 300.000000 and glue 84.618333, giving hybrid 550.657278 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 930.150916, chip thickness 300.000000 and glue 85.197556, giving hybrid 544.953361 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 925.880889, chip thickness 300.000000 and glue 70.166583, giving hybrid 555.714305 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 926.685244, chip thickness 300.000000 and glue 74.013889, giving hybrid 552.671355 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 926.425684, chip thickness 300.000000 and glue 76.303861, giving hybrid 550.121823 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 923.317476, chip thickness 300.000000 and glue 68.559639, giving hybrid 554.757837 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 923.455988, chip thickness 300.000000 and glue 70.195417, giving hybrid 553.260571 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 928.205344, chip thickness 300.000000 and glue 76.532250, giving hybrid 551.673094 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.858191, chip thickness 300.000000 and glue 90.908250, giving hybrid 543.949941 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.003000, chip thickness 300.000000 and glue 71.440375, giving hybrid 562.562625 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_035_A_H6/3//Data__DSG2608_X_035_A_H6.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_035_A_H6/3//Results__DSG2608_X_035_A_H6.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_035_A_H6/3//Data__DSG2608_X_035_A_H6.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_035_A_H6/3//Results__DSG2608_X_035_A_H6.txt
IService::log INFO Logging status 0111 for component DSG2608_X_035_A_H6
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_035_A_H6/MetrologyHybrid_PROD_X_v2_interposer-3/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__DSG2608_X_035_A_H6.txt...
IService::install INFO Installed Results__DSG2608_X_035_A_H6.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed DSG2608_X_035_A_H6.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_017_D_H5-2.config
IService::next INFO Scheduling DSG2608-035-A6_019-D5_051-C0-1-2-3.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_017_D_H5/2/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0012169
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for DSG2608_X_035_A_H6
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component DSG2608_X_035_A_H6
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_035_A_H6/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed DSG2608_X_035_A_H6.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Date
2026-08-18T20:42:24.866+00:00
Operator
LM
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files DSG2608_X_035_A_H6/20USBHX2008461
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files DSG2608_X_035_A_H6/20USBHX2008461
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_powerCycleTest_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2008461_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_035_A_H6_GAIN_TEST.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component DSG2608_X_035_A_H6
IService::install INFO Installing output directory to /home/data/modules/DSG2608_X_035_A_H6/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008461_20260818_2_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008461_20260818_2_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2008461_20260818_2_NO_BURNIN.json...
IService::install INFO Installed DSG2608_X_035_A_H6.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008451_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008451_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008451_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008451_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008451_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008451_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008451_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008451_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008451_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008451_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008452_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008452_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008452_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008452_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008452_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008452_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008452_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008452_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008452_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008452_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008453_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008453_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008453_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008453_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008453_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008453_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008453_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008453_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008453_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008453_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008454_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008454_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008454_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008454_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008454_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008454_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008454_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008454_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008454_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008454_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008455_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008455_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008455_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008455_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008455_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008455_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008455_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008455_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008455_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008455_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008461_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008461_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008461_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008461_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008461_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008461_20260818_2_NO_BURNIN.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail INFO Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008461_20260818_2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008461_20260818_2_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008461_20260818_2_3PG_BURNIN.json
ElectricalSvc::PassFail INFO Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008461_20260818_2_NO_BURNIN.json
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for DSG2608_X_035_A_H6
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0012169
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAH1023014
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370293
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370292
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370291
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370290
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370289
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370288
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370287
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370286
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370285
MetaData::getLocalName WARNING Could not find a local name for identifier 20USGAA1370284
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.