Results for DSG2608_X_051_C_H6


The information on this page was generated on Sat Aug 29 06:44:26 2026 (America/Los_Angeles).
You may click the button below to manually regenerate the content.

Basic Information for DSG2608_X_051_C_H6


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier UCSC-X-1329
Serial Number 20USBHX2008522
Batch PRODUCTION_UCSC
Assembled True
Completed False
Current Location SCIPP, UC Santa Cruz
Manufacture ID DSG2608_X_051_C_H6
User SCIPP Module Institute Account

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2026-08-17T19:36:51.819Z
HCC Chip HCCSTARV1 2026-08-19T19:02:06.669Z
ABC Chip ABCSTARV1 2026-08-19T19:02:08.420Z
ABC Chip ABCSTARV1 2026-08-19T19:02:10.128Z
ABC Chip ABCSTARV1 2026-08-19T19:02:11.823Z
ABC Chip ABCSTARV1 2026-08-19T19:02:13.545Z
ABC Chip ABCSTARV1 2026-08-19T19:02:15.216Z
ABC Chip ABCSTARV1 2026-08-19T19:02:16.921Z
ABC Chip ABCSTARV1 2026-08-19T19:02:18.614Z
ABC Chip ABCSTARV1 2026-08-19T19:02:20.358Z
ABC Chip ABCSTARV1 2026-08-19T19:02:22.078Z
ABC Chip ABCSTARV1 2026-08-19T19:02:23.892Z
Hybrid Interposer 2026-08-17T19:36:47.423Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel
Module 2026-08-26T14:13:29.840Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2026-08-17T19:59:43.925Z
Visual Inspection 2026-08-18T22:51:50.740Z
ASIC Metrology 2026-08-17T22:55:12.616Z
Wire bonding 2026-08-18T22:51:50.740Z
Pedestal Trim Burn In 2026-08-20T14:11:08.000Z
Strobe Delay Burn In 2026-08-20T14:11:15.000Z
Response Curve Burn In 2026-08-20T14:12:47.000Z
Noise Occupancy Burn In 2026-08-20T14:21:41.000Z

Glue weight for DSG2608_X_051_C_H6


Shown below are results for the glue weight measurements

IService::UPLOADDB                         INFO                Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB                    INFO                Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component DSG2608_X_051_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2608_X_051_C_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed 20USBHX2008522_image.jpg...
IService::install                          INFO                Installed DB_COMMENTS.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed DSG2608_X_051_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!

MetadataValue
Component type
Operator KA,LM
Date 2026-08-17T19:59:43.925+00:00
Program ASIC-X-PPB.SRC
FieldWeight/Volume
Assummed density of glue 1.077
Total volume of ASIC glue [uL] 41.697
Volume per glue dot [nL] 801.869
Weight of glue under ASICs [mg] 44.900
Weights of bare hybrid [g] 2.475
Weights of stuffed hybrid [g] 2.520

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               429.171000 +/- 6.763250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               29.956625 +/- 9.157210 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             399.214375
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 99.214375 +/- 12.433666 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 400.214375 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               425.872500 +/- 1.532500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               38.005000 +/- 6.787833 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             387.867500
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.867500 +/- 8.568736 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.867500 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               420.641500 +/- 1.702750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               33.028000 +/- 6.814667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             387.613500
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.613500 +/- 8.622009 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.613500 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               415.071000 +/- 1.781500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               34.942222 +/- 7.136167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             380.128778
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 80.128778 +/- 8.893740 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 381.128778 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               413.545750 +/- 1.215500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               35.032444 +/- 7.766333 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             378.513306
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 78.513306 +/- 9.316296 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 379.513306 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               411.821250 +/- 0.630000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               35.368333 +/- 6.524000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             376.452917
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 76.452917 +/- 8.243754 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 377.452917 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               409.076250 +/- 2.352750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               39.827222 +/- 6.294167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             369.249028
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 69.249028 +/- 8.375677 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 370.249028 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               410.111000 +/- 1.386500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               39.631889 +/- 7.385500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             370.479111
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 70.479111 +/- 9.025962 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 371.479111 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               415.602500 +/- 0.817000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               41.103444 +/- 6.000833 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             374.499056
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 74.499056 +/- 7.853502 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 375.499056 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               420.455750 +/- 1.489000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               41.671000 +/- 6.878028 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             378.784750
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 78.784750 +/- 8.632751 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 379.784750 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               419.786000 +/- 0.437500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               35.556500 +/- 6.219534 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             384.229500
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.229500 +/- 7.992122 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.229500 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 939.296500, chip thickness 300.000000 and glue 99.214375, giving hybrid 540.082125 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 932.347420, chip thickness 300.000000 and glue 87.867500, giving hybrid 544.479920 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 929.258864, chip thickness 300.000000 and glue 87.613500, giving hybrid 541.645364 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 925.536217, chip thickness 300.000000 and glue 80.128778, giving hybrid 545.407439 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 926.458872, chip thickness 300.000000 and glue 78.513306, giving hybrid 547.945566 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 926.877650, chip thickness 300.000000 and glue 76.452917, giving hybrid 550.424734 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 924.713927, chip thickness 300.000000 and glue 69.249028, giving hybrid 555.464900 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 924.719504, chip thickness 300.000000 and glue 70.479111, giving hybrid 554.240393 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 928.979240, chip thickness 300.000000 and glue 74.499056, giving hybrid 554.480184 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 933.870229, chip thickness 300.000000 and glue 78.784750, giving hybrid 555.085479 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 930.162500, chip thickness 300.000000 and glue 84.229500, giving hybrid 545.933000 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_051_C_H6/1//Data__DSG2608_X_051_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_051_C_H6/1//Results__DSG2608_X_051_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_051_C_H6/1//Data__DSG2608_X_051_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//DSG2608_X_051_C_H6/1//Results__DSG2608_X_051_C_H6.txt
IService::log                              INFO                Logging status 0111 for component DSG2608_X_051_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2608_X_051_C_H6/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__DSG2608_X_051_C_H6.txt...
IService::install                          INFO                Installed Results__DSG2608_X_051_C_H6.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed DSG2608_X_051_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0012855
MetadataValue
Component type X
Operator LM
Date 2026-08-17T22:55:12.616+00:00
Program version MetrologyHybrid_PROD_X_v2_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thin_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Wirebonding for DSG2608_X_051_C_H6


Wirebonding summaries will be given below

WireBondSvc::run                           INFO                Loading group FAILED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run                           INFO                Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB                         INFO                Working on test code WIRE_BONDING
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component DSG2608_X_051_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2608_X_051_C_H6/HybridBonding_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed DSG2608_X_051_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetadataValue
Date 2026-08-18T22:51:50.740+00:00
Operator LM
Bonder hk1
Version v1
Bond numberTypeComment

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files DSG2608_X_051_C_H6/20USBHX2008522
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files DSG2608_X_051_C_H6/20USBHX2008522
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2008522_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2008522_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2008522_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2008522_20260819_15_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2008522_20260819_15_NO_BURNIN.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//DSG2608_X_051_C_H6_GAIN_TEST.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 0111 for component DSG2608_X_051_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/DSG2608_X_051_C_H6/BurnInHybrids_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008522_20260819_15_PEDESTAL_TRIM_BURNIN.json...
IService::install                          INFO                Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008522_20260819_15_STROBE_DELAY_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_RESPONSE_CURVE_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_3PG_BURNIN.json...
IService::install                          INFO                Installed DB_READY_NO_BURNIN_SN20USBHX2008522_20260819_15_NO_BURNIN.json...
IService::install                          INFO                Installed DSG2608_X_051_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008512_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008512_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008512_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008512_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008512_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008512_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008512_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008512_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008512_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008512_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008513_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008513_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008513_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008513_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008513_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008513_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008513_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008513_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008513_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008513_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008514_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008514_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008514_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008514_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008514_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008514_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008514_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008514_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008514_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008514_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008515_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008515_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008515_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008515_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008515_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008515_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008515_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008515_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008515_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008515_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008522_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008522_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008522_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008522_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008522_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008522_20260819_15_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2008522_20260819_15_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2008522_20260819_15_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2008522_20260819_15_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2008522_20260819_15_NO_BURNIN.json
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for DSG2608_X_051_C_H6
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0012855
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAH1023025
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370414
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370413
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370412
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370411
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370410
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370409
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370408
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370407
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370406
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USGAA1370405

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.