Results for GPC2225_X_011_C_H6


The information on this page was generated on Tue Mar 31 11:12:30 2026 (probably UTC).
You may click the button below to manually regenerate the content.

Basic Information for GPC2225_X_011_C_H6


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier UCSC-X-0378
Serial Number 20USBHX2002243
Batch PRESERIES_UCSC
Assembled True
Completed True
Current Location STFC Rutherford Appleton Laboratory
Manufacture ID GPC2225_X_011_C_H6
User SCIPP Module Institute Account

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2025-03-07T19:36:19.704Z
HCC Chip HCCSTARV1 2025-03-11T22:06:47.175Z
ABC Chip ABCSTARV1 2025-03-11T22:06:47.621Z
ABC Chip ABCSTARV1 2025-03-11T22:06:48.077Z
ABC Chip ABCSTARV1 2025-03-11T22:06:48.543Z
ABC Chip ABCSTARV1 2025-03-11T22:06:49.000Z
ABC Chip ABCSTARV1 2025-03-11T22:06:49.466Z
ABC Chip ABCSTARV1 2025-03-11T22:06:49.913Z
ABC Chip ABCSTARV1 2025-03-11T22:06:50.373Z
ABC Chip ABCSTARV1 2025-03-11T22:06:50.832Z
ABC Chip ABCSTARV1 2025-03-11T22:06:51.267Z
ABC Chip ABCSTARV1 2025-03-11T22:06:51.735Z
Hybrid Interposer 2025-03-07T19:36:17.993Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel
Module 2025-03-21T18:53:02.624Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2025-03-07T19:42:36.715Z
Visual Inspection 2025-03-10T23:00:03.671Z
Wire bonding 2025-03-10T23:00:03.671Z
Pedestal Trim Burn In 2025-03-11T22:34:49.000Z
Strobe Delay Burn In 2025-03-11T22:34:56.000Z
Response Curve Burn In
Noise Occupancy Burn In 2025-03-11T22:42:45.000Z
Pedestal Trim TC 2025-03-25T00:01:43.000Z
Strobe Delay TC 2025-03-25T00:01:43.000Z
Response Curve TC 2025-03-25T00:01:43.000Z
Noise Occupancy TC 2025-03-25T00:01:43.000Z
Pedestal Trim PPA 2025-05-28T16:51:44.000Z
Response Curve PPA 2025-05-28T16:55:44.000Z
Strobe Delay PPA 2025-05-28T16:52:18.000Z
Noise Occupancy PPA 2025-05-28T17:10:35.000Z
ASIC Metrology 2025-03-07T22:05:06.324Z

Glue weight for GPC2225_X_011_C_H6


Shown below are results for the glue weight measurements

IService::UPLOADDB                         INFO                Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB                    INFO                Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component GPC2225_X_011_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2225_X_011_C_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed 20USBHX2002243_IMG_0114.jpeg...
IService::install                          INFO                Installed DB_COMMENTS.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2225_X_011_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!

MetadataValue
Component type
Operator QFP, LM
Date 2025-03-07T19:42:36.715+00:00
Program ASIC_X_PPB.SRC
FieldWeight/Volume
Assummed density of glue 1.077
Total volume of ASIC glue [uL] 38.725
Volume per glue dot [nL] 744.721
Weight of glue under ASICs [mg] 41.700
Weights of bare hybrid [g] 2.984
Weights of stuffed hybrid [g] 3.026

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               456.109500 +/- 3.816750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               56.083750 +/- 6.719105 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             400.025750
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 100.025750 +/- 9.204019 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 401.025750 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               442.619000 +/- 2.049500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               52.303222 +/- 5.873000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             390.315778
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.315778 +/- 7.980763 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.315778 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               435.556500 +/- 1.413750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               51.493333 +/- 7.362667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             384.063167
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.063167 +/- 9.011523 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.063167 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               427.120500 +/- 0.788750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               43.098111 +/- 6.042167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             384.022389
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.022389 +/- 7.882253 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.022389 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               423.156500 +/- 1.686750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               43.169556 +/- 5.136333 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             379.986944
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 79.986944 +/- 7.363902 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 380.986944 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               419.265000 +/- 0.545000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               48.154222 +/- 4.976500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             371.110778
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 71.110778 +/- 7.075491 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 372.110778 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               416.497000 +/- 1.206250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               45.209889 +/- 8.716667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             371.287111
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 71.287111 +/- 10.121033 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 372.287111 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               413.951750 +/- 0.398000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               40.701778 +/- 7.783667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             373.249972
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 73.249972 +/- 9.259799 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 374.249972 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               412.662500 +/- 0.359750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               48.076444 +/- 6.249667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             364.586056
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 64.586056 +/- 8.011726 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 365.586056 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               413.803250 +/- 2.376500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               41.355750 +/- 12.209082 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             372.447500
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 72.447500 +/- 13.405575 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 373.447500 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               409.859500 +/- 2.077750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               15.181625 +/- 11.282773 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             394.677875
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 94.677875 +/- 12.514711 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 395.677875 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 999.457750, chip thickness 300.000000 and glue 100.025750, giving hybrid 599.432000 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 994.256468, chip thickness 300.000000 and glue 90.315778, giving hybrid 603.940691 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 991.514328, chip thickness 300.000000 and glue 84.063167, giving hybrid 607.451162 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 987.079874, chip thickness 300.000000 and glue 84.022389, giving hybrid 603.057485 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 987.713698, chip thickness 300.000000 and glue 79.986944, giving hybrid 607.726753 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 988.049132, chip thickness 300.000000 and glue 71.110778, giving hybrid 616.938354 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 988.014814, chip thickness 300.000000 and glue 71.287111, giving hybrid 616.727703 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 986.631321, chip thickness 300.000000 and glue 73.249972, giving hybrid 613.381349 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 986.288899, chip thickness 300.000000 and glue 64.586056, giving hybrid 621.702843 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 989.535592, chip thickness 300.000000 and glue 72.447500, giving hybrid 617.088092 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 982.616500, chip thickness 300.000000 and glue 94.677875, giving hybrid 587.938625 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2225_X_011_C_H6/1//Data__GPC2225_X_011_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2225_X_011_C_H6/1//Results__GPC2225_X_011_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2225_X_011_C_H6/1//Data__GPC2225_X_011_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2225_X_011_C_H6/1//Results__GPC2225_X_011_C_H6.txt
IService::log                              INFO                Logging status 0111 for component GPC2225_X_011_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2225_X_011_C_H6/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2225_X_011_C_H6.txt...
IService::install                          INFO                Installed Results__GPC2225_X_011_C_H6.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2225_X_011_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0001376
MetadataValue
Component type X
Operator Len Morelos-Zaragoza
Date 2025-03-07T22:05:06.324+00:00
Program version MetrologyHybrid_PROD_X_v2_thick_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thick_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Wirebonding for GPC2225_X_011_C_H6


Wirebonding summaries will be given below

WireBondSvc::run                           INFO                Loading group FAILED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run                           INFO                Wirebond number(s)  296 with commment Source bond didn't stick, could not safely remove broken wire.
WireBondSvc::run                           INFO                Wirebond number(s) 292 with commment Source bond didn't stick, could not safely remove broken wire.
WireBondSvc::run                           INFO                Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB                         INFO                Working on test code WIRE_BONDING
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component GPC2225_X_011_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2225_X_011_C_H6/HybridBonding_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2225_X_011_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetadataValue
Date 2025-03-10T23:00:03.671+00:00
Operator QFP
Bonder hk2
Version v1
Bond numberTypeComment
296 FAILED_HYBRID_TO_PANEL Source bond didn't stick, could not safely remove broken wire.
292 FAILED_HYBRID_TO_PANEL Source bond didn't stick, could not safely remove broken wire.

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files GPC2225_X_011_C_H6/20USBHX2002243
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files GPC2225_X_011_C_H6/20USBHX2002243
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2225_X_011_C_H6_3PG.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2225_X_011_C_H6_NO.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2225_X_011_C_H6_PEDESTAL_TRIM.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2225_X_011_C_H6_RESPONSE_CURVE.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2225_X_011_C_H6_STROBE_DELAY.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2225_X_011_C_H6_GAIN_TEST.json
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 0111 for component GPC2225_X_011_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2225_X_011_C_H6/BurnInHybrids_PROD_v2-2/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_PEDESTAL_TRIM_BURNIN_GPC2225_X_011_C_H6_PEDESTAL_TRIM.json...
IService::install                          INFO                Installed DB_READY_STROBE_DELAY_BURNIN_GPC2225_X_011_C_H6_STROBE_DELAY.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_GPC2225_X_011_C_H6_3PG.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_GPC2225_X_011_C_H6_RESPONSE_CURVE.json...
IService::install                          INFO                Installed DB_READY_NO_BURNIN_GPC2225_X_011_C_H6_NO.json...
IService::install                          INFO                Installed GPC2225_X_011_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for GPC2225_X_011_C_H6
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0001376

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.