Results for GPC2233_X_011_B_H2


Basic Information for GPC2233_X_011_B_H2


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier UCSC-X-0185
Serial Number 20USBHX2001383
Assembled True
Completed False
Current Location SCIPP, UC Santa Cruz
Manufacture ID GPC2233_X_011_B_H2
User SCIPP Module Institute Account

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2023-06-05T22:16:09.419Z
HCC Chip HCCSTARV1 2023-06-08T22:58:38.663Z
ABC Chip ABCSTARV1 2023-06-08T22:58:39.151Z
ABC Chip ABCSTARV1 2023-06-08T22:58:39.628Z
ABC Chip ABCSTARV1 2023-06-08T22:58:40.117Z
ABC Chip ABCSTARV1 2023-06-08T22:58:40.599Z
ABC Chip ABCSTARV1 2023-06-08T22:58:41.121Z
ABC Chip ABCSTARV1 2023-06-08T22:58:41.587Z
ABC Chip ABCSTARV1 2023-06-08T22:58:42.059Z
ABC Chip ABCSTARV1 2023-06-08T22:58:42.559Z
ABC Chip ABCSTARV1 2023-06-08T22:58:43.064Z
ABC Chip ABCSTARV1 2023-06-08T22:58:43.536Z
Hybrid Interposer 2024-07-25T19:35:03.083Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel 2024-08-02T19:22:05.386Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2023-06-05T22:46:07.589Z
ASIC Metrology 2023-06-06T18:06:56.712Z
Visual Inspection 2023-06-08T17:20:55.716Z
Response Curve Burn In 2023-06-21T18:06:51.000Z
Strobe Delay Burn In 2023-06-21T18:03:24.000Z
Pedestal Trim Burn In 2023-06-21T17:58:39.000Z
Noise Occupancy Burn In
Wire bonding 2023-06-08T17:20:55.716Z
Noise Occupancy PPA
Strobe Delay PPA 2023-06-08T23:06:13.000Z
Response Curve PPA 2023-06-08T23:07:12.000Z
Pedestal Trim PPA 2023-06-08T23:06:04.000Z

Glue weight for GPC2233_X_011_B_H2


Shown below are results for the glue weight measurements

IService::UPLOADDB                         INFO                Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB                    INFO                Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 1111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/GlueWeightHybridASIC_PROD_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed 20USBHX2001383_image.jpg...
IService::install                          INFO                Installed DB_COMMENTS.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2233_X_011_B_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//GlueWeightHybridASIC_PROD_v1//20USBHX2001384.config
IService::next                             INFO                Scheduling Data_20USBHX2001384.json file to run...
IService::next                             INFO                Writing results to /home/data/output//GlueWeightHybridASIC_PROD_v1//GPC2233_X_011_B_H3/1/

MetadataValue
Component type
Operator FMM, AND
Date 2023-06-05T22:46:07.589+00:00
Program ASIC_X_PPB
FieldWeight/Volume
Assummed density of glue 1.077
Total volume of ASIC glue [uL] 41.883
Volume per glue dot [nL] 805.441
Weight of glue under ASICs [mg] 45.100
Weights of bare hybrid [g] 2.280
Weights of stuffed hybrid [g] 2.325

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeHybridThickness       INFO                Total stack up 843.564750, chip thickness 300.000000 and glue 125.034250, giving hybrid 418.530500 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 836.183093, chip thickness 300.000000 and glue 120.567861, giving hybrid 415.615232 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 832.974813, chip thickness 300.000000 and glue 120.262333, giving hybrid 412.712480 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 829.673856, chip thickness 300.000000 and glue 116.708083, giving hybrid 412.965773 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 826.515468, chip thickness 300.000000 and glue 113.536417, giving hybrid 412.979051 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 826.722205, chip thickness 300.000000 and glue 113.363722, giving hybrid 413.358482 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 828.209198, chip thickness 300.000000 and glue 113.111361, giving hybrid 415.097837 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 822.696923, chip thickness 300.000000 and glue 113.025694, giving hybrid 409.671228 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 830.866293, chip thickness 300.000000 and glue 111.373833, giving hybrid 419.492460 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 832.409764, chip thickness 300.000000 and glue 112.356625, giving hybrid 420.053139 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 832.671500, chip thickness 300.000000 and glue 113.628750, giving hybrid 419.042750 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
IService::log                              INFO                Logging status 1111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/MetrologyHybrid_PROD_X_v0-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2233_X_011_B_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H3.config
IService::next                             INFO                Scheduling GPC2233-X-11B-H0-5.txt file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyHybrid_PROD_X_v0//GPC2233_X_011_B_H3/1/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002289
MetadataValue
Component type X
Operator Kirsten Affolder
Date 2023-06-06T18:06:56.712+00:00
Program version MetrologyHybrid_PROD_X_v0/PPB_cloneable_v0_DB102
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1007.146750, chip thickness 300.000000 and glue 98.060625, giving hybrid 609.086125 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1003.703293, chip thickness 300.000000 and glue 111.279000, giving hybrid 592.424293 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1004.096290, chip thickness 300.000000 and glue 110.332583, giving hybrid 593.763707 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.540063, chip thickness 300.000000 and glue 100.516639, giving hybrid 605.023424 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.499161, chip thickness 300.000000 and glue 96.167861, giving hybrid 609.331300 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1004.574603, chip thickness 300.000000 and glue 101.391500, giving hybrid 603.183103 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1001.849437, chip thickness 300.000000 and glue 102.877111, giving hybrid 598.972326 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 997.903092, chip thickness 300.000000 and glue 102.518389, giving hybrid 595.384703 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 997.748003, chip thickness 300.000000 and glue 102.257250, giving hybrid 595.490753 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 993.065371, chip thickness 300.000000 and glue 94.407750, giving hybrid 598.657621 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 998.943500, chip thickness 300.000000 and glue 81.810750, giving hybrid 617.132750 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
IService::log                              INFO                Logging status 0111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/MetrologyHybrid_PROD_X_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2233_X_011_B_H2.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002289
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
IService::PASSFAIL                         WARNING             Service GPC2233_X_011_B_H2 has failed criteria!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
  • ✔ Component is at UCSC. OK to upload
  • Service has no required stages or transformations. Allowing for upload, but careful! OK to upload
  • ✘ Component has failed criteria!

IV

MetadataValue
Component type X
Operator Len Morelos-Zaragoza
Date 2024-07-25T19:18:51.159+00:00
Program version MetrologyHybrid_PROD_X_v2/PROD_clonable_v2_new-jig_DB102_6hybrids_thin
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1007.146750, chip thickness 300.000000 and glue 98.060625, giving hybrid 609.086125 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1003.703293, chip thickness 300.000000 and glue 111.279000, giving hybrid 592.424293 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1004.096290, chip thickness 300.000000 and glue 110.332583, giving hybrid 593.763707 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.540063, chip thickness 300.000000 and glue 100.516639, giving hybrid 605.023424 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.499161, chip thickness 300.000000 and glue 96.167861, giving hybrid 609.331300 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1004.574603, chip thickness 300.000000 and glue 101.391500, giving hybrid 603.183103 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1001.849437, chip thickness 300.000000 and glue 102.877111, giving hybrid 598.972326 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 997.903092, chip thickness 300.000000 and glue 102.518389, giving hybrid 595.384703 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 997.748003, chip thickness 300.000000 and glue 102.257250, giving hybrid 595.490753 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 993.065371, chip thickness 300.000000 and glue 94.407750, giving hybrid 598.657621 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 998.943500, chip thickness 300.000000 and glue 81.810750, giving hybrid 617.132750 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_011_B_H2/1//Data__GPC2233_X_011_B_H2.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_011_B_H2/1//Results__GPC2233_X_011_B_H2.txt
IService::log                              INFO                Logging status 0111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results__GPC2233_X_011_B_H2.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2233_X_011_B_H2.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
IService::addStageTransformation           INFO                Adding allow stage transformation from "STUFFED" to "BARE"
IService::addStageTransformation           INFO                Adding allow stage transformation from "BARE" to "SMD"
IService::addStageTransformation           INFO                Adding allow stage transformation from "FAILED_ELECTRICAL" to "SMD"
IService::addStageTransformation           INFO                Adding allow stage transformation from "SMD" to "ASIC"
IService::addStageTransformation           INFO                Adding allow stage transformation from "HV_TAB_ATTACHED" to "GLUED"
IService::addStageTransformation           INFO                Adding allow stage transformation from "HV_TAB_ATTACHED" to "GLUED"
IService::addStageTransformation           INFO                Adding allow stage transformation from "ASIC_ATTACHMENT" to "WIRE_BONDING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "GLUED" to "BONDED"
IService::addStageTransformation           INFO                Adding allow stage transformation from "BARE" to "SMD"
IService::addStageTransformation           INFO                Adding allow stage transformation from "THERMAL" to "MODULE_RCP"
IService::addStageTransformation           INFO                Adding allow stage transformation from "BONDED" to "MODULE_RCP"
IService::addStageTransformation           INFO                Adding allow stage transformation from "BURN_IN" to "MODULE_RCP"
IService::addStageTransformation           INFO                Adding allow stage transformation from "ON_WAFER" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "PROBING" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "FAILED_VI" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_A" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_C" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_T" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_X" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_B" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "ON_WAFER" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "PROBING" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "FAILED_VI" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_A" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_C" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_T" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_X" to "BOND_PULLING"
IService::addStageTransformation           INFO                Adding allow stage transformation from "CATEGORY_B" to "BOND_PULLING"
IService::addFailFlag                      INFO                Adding fail flag "FAILED_MODULE_RECEPTION"
IService::addPassFlag                      INFO                Adding passed flag "PASSED_MODULE_RECEPTION"
IService::addStageTransformation           INFO                Adding allow stage transformation from "WIRE_BONDING" to "BURN_IN"
IService::addPostStageTransformation       INFO                Adding post stage transformation from "BURN_IN" to "FINISHED_HYBRID"
IService::addPostStageTransformation       INFO                Adding post stage transformation from "FINISHED_HYBRID" to "AT_MODULE_ASSEMBLY_SITE"
IService::addStageTransformation           INFO                Adding allow stage transformation from "WIRE_BONDING" to "BURN_IN"
IService::addPostStageTransformation       INFO                Adding post stage transformation from "BURN_IN" to "FINISHED_HYBRID"
IService::addPostStageTransformation       INFO                Adding post stage transformation from "FINISHED_HYBRID" to "AT_MODULE_ASSEMBLY_SITE"
IService::addStageTransformation           INFO                Adding allow stage transformation from "BONDED" to "TESTED"
TopControl::initialize                     INFO                Running initialization...
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
VisualInspectionSvc::initialize            INFO                Writing outputs into /home/data/output//HybridFlexArrayVI_v1///1/
VisualInspectionSvc::add_general           INFO                Added a general visual inspection key with "Overall visual inspection"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Damage to array"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Damage to hybrid flex"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Component damage"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Components were missing"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Scratches were found"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Cleaning"
VisualInspectionSvc::add_hybrid_flex_...   INFO                Added a hybrid flex arrray inspection key with "Other"
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
VisualInspectionSvc::initialize            INFO                Writing outputs into /home/data/output//SensorVI_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//ASICGlueWeight///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.076811
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//ASICGlueWeight_v1///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.076811
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//GlueWeightHybridASIC_PPB_v1///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.076811
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//GlueWeightHybridASIC_PROD_v1///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.076811
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//GlueWeightHybridASIC_PROD_v2///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.076811
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//GlueWeightModule_LS_PPA///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.132242
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
GlueWeightSvc::initialize                  INFO                Writing outputs into /home/data/output//GlueWeightModule_SS_PPA///1/
GlueWeightSvc::initialize                  INFO                Calculations assuming a glue density of 1.132242
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
WireBondSvc::initialize                    INFO                Writing outputs into /home/data/output//HybridBonding_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
WireBondSvc::initialize                    INFO                Writing outputs into /home/data/output//ModuleBonding_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//HybridPullTest///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//PullTestCicorelCard///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//HybridFlexArray_PullTest_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//Powerboards_PullTest_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//ABC_PullTest_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//ABC_Wafer_PullTest_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//HCC_PullTest_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//SensorBondingQC_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//HVTabSheet_SheerTest_Before_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PullTestSvc::initialize                    INFO                Writing outputs into /home/data/output//HVTabSheet_SheerTest_After_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PictureSvc::initialize                     INFO                Writing outputs into /home/data/output//PhotoUpload///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PictureSvc::initialize                     INFO                Writing outputs into /home/data/output//PictureModule///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
PictureSvc::initialize                     INFO                Writing outputs into /home/data/output//GeneralPictures///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//PreHVTabIV///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//SensorIV_PreTabIV_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//Module_postHVTabIV_LS_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//SensorIV_PostTabIV_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//ElectricalIV///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//SensorIV_Module_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
SensorIVSvc::initialize                    INFO                Writing outputs into /home/data/output//SensorIV_AMACIV_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//SixWayJig_Y_slots///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 1 surfaces
MetrologySvc::loadReferenceFile            INFO                User didn't specify a reference file! Won't load anything!
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridMetrology///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                User didn't specify a reference file! Won't load anything!
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridPanelMetrology///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.899000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.501000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.563000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.165000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.227000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.829000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.891000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.493000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.555000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.157000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.219000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.821000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.883000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.485000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.547000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.149000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.211000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.813000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.875000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.477000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,7.319000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,7.319000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,10.555000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,10.555000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridPanelMetrology_v7///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.899000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.501000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.563000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.165000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.227000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.829000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.891000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.493000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.555000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.157000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.219000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.821000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.883000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.485000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.547000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.149000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.211000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.813000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.875000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.477000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,7.319000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,7.319000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,10.555000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,10.555000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridMetrology_v8///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.899000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.501000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.563000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.165000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.227000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.829000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.891000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.493000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.555000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.157000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.219000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.821000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.883000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.485000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.547000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.149000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.211000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.813000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.875000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.477000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,7.319000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,7.319000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,10.555000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,10.555000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridMetrology_Y_v8///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_Y.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (0.875000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (8.478000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (10.539000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (18.142000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (20.203000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (27.806000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (29.867000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (37.470000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (39.531000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (47.134000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (49.195000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (56.798000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (58.859000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (66.462000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (68.523000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (76.126000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (78.187000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (85.790000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (87.851000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (95.454000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.698000,7.315000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.629000,7.315000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.698000,10.551000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.629000,10.551000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_v10///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.899000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.501000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.563000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.165000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.227000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.829000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.891000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.493000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.555000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.157000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.219000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.821000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.883000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.485000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.547000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.149000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.211000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.813000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.875000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.477000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,7.319000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,7.319000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,10.555000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,10.555000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_v10-beta///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.899000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.501000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.563000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.165000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.227000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.829000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.891000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.493000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.555000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.157000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.219000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.821000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.883000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.485000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.547000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.149000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.211000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.813000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.875000,1.198000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.477000,1.198000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,7.319000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,7.319000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.721000,10.555000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.653000,10.555000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PPB_X_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PPB_Y_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_Y_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (0.876000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (8.478000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (10.540000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (18.142000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (20.204000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (27.806000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (29.868000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (37.470000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (39.532000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (47.134000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (49.196000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (56.798000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (58.860000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (66.462000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (68.524000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (76.126000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (78.188000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (85.790000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (87.852000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (95.454000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,7.203000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,7.203000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,11.200000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,11.200000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_Y_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_Y_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (0.876000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (8.478000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (10.540000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (18.142000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (20.204000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (27.806000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (29.868000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (37.470000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (39.532000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (47.134000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (49.196000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (56.798000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (58.860000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (66.462000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (68.524000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (76.126000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (78.188000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (85.790000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (87.852000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (95.454000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,7.203000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,7.203000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,11.200000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,11.200000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_Y_v0_interposer///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_Y_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (0.876000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_0 with (x,y) = (8.478000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (10.540000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_1 with (x,y) = (18.142000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (20.204000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_2 with (x,y) = (27.806000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (29.868000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_3 with (x,y) = (37.470000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (39.532000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_4 with (x,y) = (47.134000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (49.196000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_5 with (x,y) = (56.798000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (58.860000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_6 with (x,y) = (66.462000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (68.524000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_7 with (x,y) = (76.126000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (78.188000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_8 with (x,y) = (85.790000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (87.852000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_Y_9 with (x,y) = (95.454000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,7.203000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,7.203000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (6.696000,11.200000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_Y_0 with (x,y) = (11.628000,11.200000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v2///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v2_thick///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v2_interposer///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 11 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/hybrid_positions_X_PPB.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (0.907000,1.186000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_9 with (x,y) = (8.500900,1.186000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (10.571000,1.187000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_8 with (x,y) = (18.173000,1.187000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (20.235000,1.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_7 with (x,y) = (27.837000,1.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (29.899000,1.190000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_6 with (x,y) = (37.501000,1.190000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (39.563000,1.191000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_5 with (x,y) = (47.165000,1.191000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (49.227000,1.192000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_4 with (x,y) = (56.829000,1.192000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (58.891000,1.193000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_3 with (x,y) = (66.493000,1.193000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (68.555000,1.194000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_2 with (x,y) = (76.157000,1.194000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (78.219000,1.196000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_1 with (x,y) = (85.821000,1.196000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (87.883000,1.197000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point ABC_X_0 with (x,y) = (95.485000,1.197000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,7.188000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,7.188000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (6.727000,11.187000) and instance 2
MetrologySvc::loadReferenceFile            INFO                Loaded reference point HCC_X_0 with (x,y) = (11.658000,11.187000) and instance 3
MetrologySvc::initialize                   INFO                Identified component HYBRID with test type HYBRID_METROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//HybridToSensorMetrology_v2a///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 2 surfaces
MetrologySvc::loadReferenceFile            INFO                User didn't specify a reference file! Won't load anything!
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_v8///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 18 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.788000,39.673000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (24.951000,24.611000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.201000,24.611000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_v8a///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 18 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.788000,39.673000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (24.951000,24.611000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.201000,24.611000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PPA_SS_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 32 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_SS_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.788000,63.873000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,63.873000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P1 with (x,y) = (0.812000,33.753000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P2 with (x,y) = (97.188000,33.753000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (24.951000,48.811000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.201000,48.811000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PPB_SS_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 33 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_SS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,63.861000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,63.861000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P1 with (x,y) = (0.812000,33.753000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P2 with (x,y) = (97.188000,33.753000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (23.200000,48.849000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.273000,47.674000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PPB_SS_wuerth_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 33 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_SS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,63.861000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,63.861000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P1 with (x,y) = (0.812000,33.753000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P2 with (x,y) = (97.188000,33.753000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (23.200000,48.849000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.273000,47.674000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PPB_LS_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 19 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,39.660000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (93.273000,23.474000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (23.200000,24.649000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PROD_LS_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 19 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,39.660000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (93.273000,23.474000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (23.200000,24.649000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PROD_SS_v1///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 33 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_SS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,63.861000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,63.861000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P1 with (x,y) = (0.812000,33.753000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_Y_P2 with (x,y) = (97.188000,33.753000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (23.200000,48.849000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (93.273000,47.674000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PROD_LS_v1_thin///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 19 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,39.660000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (93.273000,23.474000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (23.200000,24.649000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PROD_LS_v1_interposer///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 19 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,39.660000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (93.273000,23.474000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (23.200000,24.649000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//MetrologyModules_PROD_LS_v1_thin_interposer///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 19 surfaces
MetrologySvc::loadReferenceFile            INFO                Loading reference file data/metrology/module_LS_PPB_positions.txt...
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P1 with (x,y) = (0.780000,39.660000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point H_X_P2 with (x,y) = (97.188000,39.673000) and instance 1
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P1 with (x,y) = (93.273000,23.474000) and instance 0
MetrologySvc::loadReferenceFile            INFO                Loaded reference point PB_P2 with (x,y) = (23.200000,24.649000) and instance 1
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//ModuleLS_Bow_PPA_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 1 surfaces
MetrologySvc::loadReferenceFile            INFO                User didn't specify a reference file! Won't load anything!
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::initialize                   INFO                Writing outputs into /home/data/output//ModuleSS_Bow_PPA_v0///1/
MetrologySvc::initialize                   INFO                Configured to run with a total of 1 surfaces
MetrologySvc::loadReferenceFile            INFO                User didn't specify a reference file! Won't load anything!
MetrologySvc::initialize                   INFO                Identified component MODULE with test type MMETROLOGY
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
ElectricalSvc::initialize                  INFO                Writing outputs into /home/data/output//ElectricalHybrids///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
ElectricalSvc::initialize                  INFO                Writing outputs into /home/data/output//ElectricalHybrids_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
ElectricalSvc::initialize                  INFO                Writing outputs into /home/data/output//BurnInHybrids_PPB_v1///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
ElectricalSvc::initialize                  INFO                Writing outputs into /home/data/output//BurnInHybrids_PROD_v2///1/
IService::INITIALIZE()                     INFO                User did not provide a MetaData object. Creating a fresh one now
ElectricalSvc::initialize                  INFO                Writing outputs into /home/data/output//ElectricalModules_PPA_v1///1/
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArrayVI_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorVI_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ASICGlueWeight ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ASICGlueWeight_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightHybridASIC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightHybridASIC_PROD_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightHybridASIC_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PPB_X_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PPB_Y_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Serivce MetrologyHybrid_PROD_X_v2_thick_interposer has 5 files to process! Proceeding...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2230_X_018_B_H0-1.config
IService::next                             INFO                Scheduling GPC2230-X-018-B0_interposed.txt file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2230_X_018_B_H0/1/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002289
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::PassFail                     WARNING             Identified a total of 11 objects outside tolerence!!
MetrologySvc::setTolerenceDetailed         WARNING             Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setTolerenceDetailed         WARNING             Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setTolerenceDetailed         WARNING             Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed         WARNING             Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
  • ✔ Component is at UCSC. OK to upload
  • Service has no required stages or transformations. Allowing for upload, but careful! OK to upload

MetadataValue
Component type X
Operator Len Morelos-Zaragoza
Date 2024-07-25T19:18:51.159+00:00
Program version MetrologyHybrid_PROD_X_v2_thick_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thick_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Wirebonding for GPC2233_X_011_B_H2


Wirebonding summaries will be given below

WireBondSvc::run                           INFO                Loading group FAILED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run                           INFO                Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB                         INFO                Working on test code WIRE_BONDING
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 1111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/HybridBonding_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2233_X_011_B_H2.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//HybridBonding_v1//GPC2233_X_011_B_H3.config
IService::next                             INFO                Scheduling HybridBonding_GPC2233_X_011_B_H3.json file to run...
IService::next                             INFO                Writing results to /home/data/output//HybridBonding_v1//GPC2233_X_011_B_H3/1/
MetadataValue
Date 2023-06-08T17:20:55.716+00:00
Operator FMM
Bonder hk1
Version v1
Bond numberTypeComment

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files GPC2233_X_011_B_H2/20USBHX2001383
ElectricalSvc::getListOfFilesFromDir       INFO                Found file GPC2233_X_011_B_H2_20230608.txt
ElectricalSvc::getListOfFilesFromDir       INFO                Found file GPC2233_X_011_B_H2_RC_4_3.txt
ElectricalSvc::getListOfFilesFromDir       INFO                Found file GPC2233_X_011_B_H2_RC_4_6.txt
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files GPC2233_X_011_B_H2/20USBHX2001383
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_20230608_4_1_PEDESTAL_TRIM_PPA.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_20230608_4_2_STROBE_DELAY_PPA.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_20230608_4_3_RESPONSE_CURVE_PPA.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_20230608_4_6_RESPONSE_CURVE_PPA.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_20230608_4_16_NO_PPA.json
ElectricalSvc::read                        INFO                Found 2 results files...
ElectricalSvc::read                        INFO                Analyzing test ResponseCurve for component GPC2233_X_011_B_H2
ElectricalSvc::read                        INFO                Detected 0 dead channels
ElectricalSvc::read                        INFO                Detected 0 stuck channels
ElectricalSvc::read                        INFO                Detected 0 low gain channels
ElectricalSvc::read                        INFO                Detected 0 high gain channels
ElectricalSvc::read                        INFO                Detected 0 low offset channels
ElectricalSvc::read                        INFO                Detected 0 high offset channels
ElectricalSvc::read                        INFO                Detected 2558 unbonded channels
ElectricalSvc::read                        INFO                Detected 0 part bonded channels
ElectricalSvc::read                        INFO                Detected 0 high noise channels
ElectricalSvc::read                        INFO                Detected 0 inefficient channels
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//ElectricalHybrids_PPB_v1//GPC2233_X_011_B_H2_GAIN_TEST.json
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_PPA
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_PPA
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_PPA
IService::UPLOADDB                         INFO                Working on test code NO_PPA
IService::log                              INFO                Logging status 1111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/ElectricalHybrids_PPB_v1-1/
IService::install                          INFO                File already installed: warningLog.txt...
IService::install                          INFO                File already installed: errorLog.txt...
IService::install                          INFO                File already installed: infoLog.txt...
IService::install                          INFO                File already installed: Gain_Channel1D.pdf...
IService::install                          INFO                File already installed: DB_READY_PEDESTAL_TRIM_PPA_GPC2233_X_011_B_H2_20230608_4_1_PEDESTAL_TRIM_PPA.json...
IService::install                          INFO                File already installed: DB_READY_STROBE_DELAY_PPA_GPC2233_X_011_B_H2_20230608_4_2_STROBE_DELAY_PPA.json...
IService::install                          INFO                File already installed: DB_READY_RESPONSE_CURVE_PPA_GPC2233_X_011_B_H2_20230608_4_3_RESPONSE_CURVE_PPA.json...
IService::install                          INFO                File already installed: DB_READY_RESPONSE_CURVE_PPA_GPC2233_X_011_B_H2_20230608_4_6_RESPONSE_CURVE_PPA.json...
IService::install                          INFO                File already installed: DB_READY_NO_PPA_GPC2233_X_011_B_H2_20230608_4_16_NO_PPA.json...
IService::install                          INFO                File already installed: GPC2233_X_011_B_H2.root...
IService::install                          INFO                File already installed: status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//ElectricalHybrids_PPB_v1//GPC2233_X_011_B_H3.config
IService::next                             INFO                Scheduling Panel30_June8 file to run...
IService::next                             INFO                Writing results to /home/data/output//ElectricalHybrids_PPB_v1//GPC2233_X_011_B_H3/1/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002289
DefectNumber of channels (%)
Dead 0
Stuck 0
Low gain 0
High gain 0
Low offset 0
High offset 0
Unbonded 2558
Part bonded 0
High noise 0
Inefficient 0

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files GPC2233_X_011_B_H2/20USBHX2001383
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files GPC2233_X_011_B_H2/20USBHX2001383
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_011_B_H2_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2233_X_011_B_H2_GAIN_TEST.json
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 1111 for component GPC2233_X_011_B_H2
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_011_B_H2/BurnInHybrids_PROD_v2-1/
IService::install                          INFO                File already installed: warningLog.txt...
IService::install                          INFO                File already installed: errorLog.txt...
IService::install                          INFO                File already installed: infoLog.txt...
IService::install                          INFO                File already installed: DB_READY_PEDESTAL_TRIM_BURNIN_GPC2233_X_011_B_H2_PEDESTAL_TRIM_BURNIN.json...
IService::install                          INFO                File already installed: DB_READY_STROBE_DELAY_BURNIN_GPC2233_X_011_B_H2_STROBE_DELAY_BURNIN.json...
IService::install                          INFO                File already installed: DB_READY_RESPONSE_CURVE_BURNIN_GPC2233_X_011_B_H2_RESPONSE_CURVE_BURNIN.json...
IService::install                          INFO                File already installed: DB_READY_NO_BURNIN_GPC2233_X_011_B_H2_NO_BURNIN.json...
IService::install                          INFO                File already installed: GPC2233_X_011_B_H2.root...
IService::install                          INFO                File already installed: status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//BurnInHybrids_PROD_v2//GPC2233_X_011_B_H3.config
IService::next                             INFO                Scheduling BurnIn_June9_merged file to run...
IService::next                             INFO                Writing results to /home/data/output//BurnInHybrids_PROD_v2//GPC2233_X_011_B_H3/1/
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for GPC2233_X_011_B_H2
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002289

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.