Results for GPC2233_X_023_B_H5


Basic Information for GPC2233_X_023_B_H5


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier LBNL_STRIP_MODULES-X-0180
Serial Number 20USBHX2001573
Batch PRODUCTION_LBNL
Assembled True
Completed False
Current Location SCIPP, UC Santa Cruz
Manufacture ID 11
User Ian Dyckes

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2024-08-22T00:00:06.446Z
HCC Chip HCCSTARV1 2024-08-22T00:55:19.747Z
ABC Chip ABCSTARV1 2024-08-22T02:39:08.057Z
ABC Chip ABCSTARV1 2024-08-22T02:39:10.139Z
ABC Chip ABCSTARV1 2024-08-22T02:39:11.827Z
ABC Chip ABCSTARV1 2024-08-22T02:39:13.457Z
ABC Chip ABCSTARV1 2024-08-22T02:39:15.837Z
ABC Chip ABCSTARV1 2024-08-22T02:39:17.427Z
ABC Chip ABCSTARV1 2024-08-22T02:39:19.255Z
ABC Chip ABCSTARV1 2024-08-22T02:39:21.634Z
ABC Chip ABCSTARV1 2024-08-22T02:39:23.370Z
ABC Chip ABCSTARV1 2024-08-22T02:39:25.320Z
Hybrid Interposer 2024-09-03T18:54:16.450Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel
Module 2024-10-29T17:28:02.515Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2023-08-15T21:44:31.753Z
Visual Inspection 2024-08-22T06:54:32.547Z
ASIC Metrology 2023-08-08T22:09:55.000Z
Wire bonding 2023-08-31T21:23:58.292Z
Noise Occupancy Burn In 2024-09-04T23:55:53.000Z
Strobe Delay Burn In 2024-09-04T23:16:55.000Z
Pedestal Trim Burn In 2024-09-04T23:16:34.000Z
Response Curve Burn In 2024-09-04T23:19:19.000Z

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1000.720000, chip thickness 300.000000 and glue 105.853250, giving hybrid 594.866750 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.665714, chip thickness 300.000000 and glue 120.292417, giving hybrid 585.373298 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1001.846047, chip thickness 300.000000 and glue 114.828278, giving hybrid 587.017769 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1007.289285, chip thickness 300.000000 and glue 122.722417, giving hybrid 584.566868 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1010.832863, chip thickness 300.000000 and glue 125.300917, giving hybrid 585.531946 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1014.594807, chip thickness 300.000000 and glue 127.133389, giving hybrid 587.461418 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1011.306326, chip thickness 300.000000 and glue 123.214694, giving hybrid 588.091632 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1006.124301, chip thickness 300.000000 and glue 115.707944, giving hybrid 590.416356 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1005.628729, chip thickness 300.000000 and glue 119.912222, giving hybrid 585.716506 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 999.143487, chip thickness 300.000000 and glue 118.364500, giving hybrid 580.778987 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 997.152250, chip thickness 300.000000 and glue 109.676000, giving hybrid 587.476250 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H5/1//Data__GPC2233_X_023_B_H5.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H5/1//Results__GPC2233_X_023_B_H5.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H5/1//Data__GPC2233_X_023_B_H5.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H5/1//Results__GPC2233_X_023_B_H5.txt
IService::log                              INFO                Logging status 0111 for component GPC2233_X_023_B_H5
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_023_B_H5/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2233_X_023_B_H5.txt...
IService::install                          INFO                Installed Results__GPC2233_X_023_B_H5.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2233_X_023_B_H5.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H6-1.config
IService::next                             INFO                Scheduling GPC2233-X-023-B2-3-4-5-6_GPC2230-X-016-B6_interposed_v2.txt file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2233_X_023_B_H6/1/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002544
Measurement::addPoint                      ERROR               Unknown type ?! Ignoring!
  • ✔ Component is at UCSC. OK to upload
  • Service has no required stages or transformations. Allowing for upload, but careful! OK to upload

MetadataValue
Component type X
Operator Len Morelos-Zaragoza
Date 2024-09-03T21:00:00.109+00:00
Program version MetrologyHybrid_PROD_X_v2_thick_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thick_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files GPC2233_X_023_B_H5/20USBHX2001573
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files GPC2233_X_023_B_H5/20USBHX2001573
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_023_B_H5_NO.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_023_B_H5_RESPONSE_CURVE.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_023_B_H5_STROBE_DELAY.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_023_B_H5_PEDESTAL_TRIM.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle GPC2233_X_023_B_H5_3PG.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2233_X_023_B_H5_GAIN_TEST.json
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 0111 for component GPC2233_X_023_B_H5
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2233_X_023_B_H5/BurnInHybrids_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_PEDESTAL_TRIM_BURNIN_GPC2233_X_023_B_H5_PEDESTAL_TRIM.json...
IService::install                          INFO                Installed DB_READY_STROBE_DELAY_BURNIN_GPC2233_X_023_B_H5_STROBE_DELAY.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_GPC2233_X_023_B_H5_RESPONSE_CURVE.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_GPC2233_X_023_B_H5_3PG.json...
IService::install                          INFO                Installed DB_READY_NO_BURNIN_GPC2233_X_023_B_H5_NO.json...
IService::install                          INFO                Installed GPC2233_X_023_B_H5.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//BurnInHybrids_PROD_v2//GPC2233_X_023_B_H4-1.config
IService::next                             INFO                Scheduling Test_BurnIn_LBNL_009_010_merged file to run...
IService::next                             INFO                Writing results to /home/data/output//BurnInHybrids_PROD_v2//GPC2233_X_023_B_H4/1/
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for GPC2233_X_023_B_H5
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0002544

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.