IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2320_X_005_A_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2320_X_005_A_H2/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2003216_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2320_X_005_A_H2.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
KA
Date
2025-07-30T20:50:36.586+00:00
Program
ASIC_X_PPB.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.118
Volume per glue dot [nL]
771.509
Weight of glue under ASICs [mg]
43.200
Weights of bare hybrid [g]
2.954
Weights of stuffed hybrid [g]
2.997
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 461.728750 +/- 3.732750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 56.714500 +/- 9.959599 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 405.014250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 105.014250 +/- 11.752746 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 406.014250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 456.113750 +/- 2.186250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 48.739333 +/- 6.113333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 407.374417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 107.374417 +/- 8.194665 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 408.374417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 451.100250 +/- 2.702750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 48.142667 +/- 7.790333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 402.957583
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 102.957583 +/- 9.643348 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 403.957583 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 443.863500 +/- 3.835500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 50.063778 +/- 7.812333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 393.799722
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 93.799722 +/- 10.037112 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 394.799722 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 442.454750 +/- 2.513000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 49.985000 +/- 4.737333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 392.469750
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 92.469750 +/- 7.331950 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 393.469750 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 439.154000 +/- 2.108750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 48.100222 +/- 5.907833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 391.053778
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 91.053778 +/- 8.021803 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 392.053778 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 436.809500 +/- 2.379000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 47.743667 +/- 9.527000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 389.065833
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 89.065833 +/- 11.019227 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 390.065833 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 434.944000 +/- 2.882250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 42.027667 +/- 12.774500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 392.916333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 92.916333 +/- 14.017675 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 393.916333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 433.952000 +/- 2.845250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 45.111667 +/- 12.235833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 388.840333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 88.840333 +/- 13.520764 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 389.840333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 434.751000 +/- 2.676250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 41.768125 +/- 13.724766 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 392.982875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 92.982875 +/- 14.850303 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 393.982875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 443.127750 +/- 0.497250 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 35.672000 +/- 6.082886 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 407.455750
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 107.455750 +/- 7.889788 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 408.455750 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 1004.489500, chip thickness 300.000000 and glue 105.014250, giving hybrid 599.475250 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 999.693182, chip thickness 300.000000 and glue 107.374417, giving hybrid 592.318765 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 996.562748, chip thickness 300.000000 and glue 102.957583, giving hybrid 593.605165 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 990.895236, chip thickness 300.000000 and glue 93.799722, giving hybrid 597.095514 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 991.669985, chip thickness 300.000000 and glue 92.469750, giving hybrid 599.200235 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 990.227277, chip thickness 300.000000 and glue 91.053778, giving hybrid 599.173499 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 988.209230, chip thickness 300.000000 and glue 89.065833, giving hybrid 599.143397 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 986.151937, chip thickness 300.000000 and glue 92.916333, giving hybrid 593.235603 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 982.568615, chip thickness 300.000000 and glue 88.840333, giving hybrid 593.728282 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 983.136912, chip thickness 300.000000 and glue 92.982875, giving hybrid 590.154037 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 991.537000, chip thickness 300.000000 and glue 107.455750, giving hybrid 584.081250 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H2/1//Data__GPC2320_X_005_A_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H2/1//Results__GPC2320_X_005_A_H2.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H2/1//Data__GPC2320_X_005_A_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H2/1//Results__GPC2320_X_005_A_H2.txt
IService::log INFO Logging status 0111 for component GPC2320_X_005_A_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2320_X_005_A_H2/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2320_X_005_A_H2.txt...
IService::install INFO Installed Results__GPC2320_X_005_A_H2.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2320_X_005_A_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H3-1.config
IService::next INFO Scheduling GPC2337-021-A6_GPC2320-005-A0-A1-A2-A3-A4.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2320_X_005_A_H3/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0003206
Measurement::addPoint ERROR Unknown type ?! Ignoring!
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2320_X_005_A_H2
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2320_X_005_A_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2320_X_005_A_H2/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2320_X_005_A_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2320_X_005_A_H3-1.config
IService::next INFO Scheduling HybridBonding_GPC2320_X_005_A_H3-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2320_X_005_A_H3/1/
Metadata
Value
Date
2025-07-31T23:42:31.499+00:00
Operator
LM
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files GPC2320_X_005_A_H2/20USBHX2003216
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files GPC2320_X_005_A_H2/20USBHX2003216
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003216_20250801_6_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003216_20250801_6_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003216_20250801_6_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003216_20250801_6_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003216_20250801_6_NO_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2320_X_005_A_H2_GAIN_TEST.json
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component GPC2320_X_005_A_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2320_X_005_A_H2/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003216_20250801_6_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003216_20250801_6_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003216_20250801_6_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003216_20250801_6_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2003216_20250801_6_NO_BURNIN.json...
IService::install INFO Installed GPC2320_X_005_A_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//BurnInHybrids_PROD_v2//GPC2320_X_005_A_H3-1.config
IService::next INFO Scheduling Burnin_Panel_46_53_August1 file to run...
IService::next INFO Writing results to /home/data/output//BurnInHybrids_PROD_v2//GPC2320_X_005_A_H3/1/
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for GPC2320_X_005_A_H2
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0003206