The information on this page was generated on Tue Mar 31 11:26:35 2026 (probably UTC). You may click the button below to manually regenerate the content.
Basic Information for GPC2328_X_002_A_H0
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2328_X_002_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_002_A_H0/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2003085_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2328_X_002_A_H0.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//GlueWeightHybridASIC_PROD_v2//20USBHX2003085-2.config
IService::next INFO Scheduling Data_20USBHX2003085-2.json file to run...
IService::next INFO Writing results to /home/data/output//GlueWeightHybridASIC_PROD_v2//GPC2328_X_002_A_H0/2/
Metadata
Value
Component type
Operator
KA
Date
2025-07-16T18:08:24.504+00:00
Program
ASIC-X.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
42.162
Volume per glue dot [nL]
810.799
Weight of glue under ASICs [mg]
45.400
Weights of bare hybrid [g]
2.856
Weights of stuffed hybrid [g]
2.901
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 456.576750 +/- 3.404250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 38.184500 +/- 11.092561 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 418.392250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 118.392250 +/- 12.634628 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 419.392250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 449.211250 +/- 1.794750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 47.665111 +/- 6.542833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 401.546139
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 101.546139 +/- 8.427918 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 402.546139 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 444.401750 +/- 2.922750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 50.099667 +/- 9.178333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 394.302083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 94.302083 +/- 10.852846 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 395.302083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 438.942000 +/- 2.913000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 42.743889 +/- 9.000500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 396.198111
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 96.198111 +/- 10.700214 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 397.198111 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 436.071250 +/- 2.966750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 44.092222 +/- 8.846500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 391.979028
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 91.979028 +/- 10.585942 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 392.979028 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 433.510500 +/- 2.419750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 45.814667 +/- 8.586167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 387.695833
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.695833 +/- 10.226312 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.695833 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 431.450250 +/- 2.458500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 39.072000 +/- 9.780667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 392.378250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 92.378250 +/- 11.256361 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 393.378250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 430.406000 +/- 2.140750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 42.553000 +/- 11.968167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 387.853000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.853000 +/- 13.146095 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.853000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 431.327750 +/- 3.060500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 39.419333 +/- 9.296500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 391.908417
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 91.908417 +/- 10.990522 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 392.908417 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 433.656000 +/- 2.193250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 31.986750 +/- 10.521395 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 401.669250
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 101.669250 +/- 11.853696 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 402.669250 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 440.819000 +/- 0.755500 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 50.086000 +/- 1.252640 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 390.733000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.733000 +/- 5.209596 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.733000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 1000.958000, chip thickness 300.000000 and glue 118.392250, giving hybrid 582.565750 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 995.367310, chip thickness 300.000000 and glue 101.546139, giving hybrid 593.821172 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 992.240550, chip thickness 300.000000 and glue 94.302083, giving hybrid 597.938467 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 988.166474, chip thickness 300.000000 and glue 96.198111, giving hybrid 591.968363 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 987.288668, chip thickness 300.000000 and glue 91.979028, giving hybrid 595.309641 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 986.387802, chip thickness 300.000000 and glue 87.695833, giving hybrid 598.691969 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 984.449973, chip thickness 300.000000 and glue 92.378250, giving hybrid 592.071723 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 981.930598, chip thickness 300.000000 and glue 87.853000, giving hybrid 594.077598 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 981.168815, chip thickness 300.000000 and glue 91.908417, giving hybrid 589.260399 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 983.077823, chip thickness 300.000000 and glue 101.669250, giving hybrid 581.408573 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 989.633000, chip thickness 300.000000 and glue 90.733000, giving hybrid 598.900000 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_002_A_H0/1//Data__GPC2328_X_002_A_H0.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_002_A_H0/1//Results__GPC2328_X_002_A_H0.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_002_A_H0/1//Data__GPC2328_X_002_A_H0.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_002_A_H0/1//Results__GPC2328_X_002_A_H0.txt
IService::log INFO Logging status 0111 for component GPC2328_X_002_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_002_A_H0/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2328_X_002_A_H0.txt...
IService::install INFO Installed Results__GPC2328_X_002_A_H0.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2328_X_002_A_H0.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0004170
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2328_X_002_A_H0
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2328_X_002_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_002_A_H0/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2328_X_002_A_H0.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2328_X_007_C_H1-1.config
IService::next INFO Scheduling HybridBonding_GPC2328_X_007_C_H1-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2328_X_007_C_H1/1/
Metadata
Value
Date
2025-07-16T21:56:59.255+00:00
Operator
LM
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files GPC2328_X_002_A_H0/20USBHX2003085
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files GPC2328_X_002_A_H0/20USBHX2003085
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003085_20250716_6_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003085_20250716_6_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003085_20250716_6_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003085_20250716_6_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2003085_20250716_6_STROBE_DELAY_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2328_X_002_A_H0_GAIN_TEST.json
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component GPC2328_X_002_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_002_A_H0/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003085_20250716_6_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003085_20250716_6_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003085_20250716_6_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003085_20250716_6_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2003085_20250716_6_NO_BURNIN.json...
IService::install INFO Installed GPC2328_X_002_A_H0.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//BurnInHybrids_PROD_v2//GPC2328_X_007_C_H2-1.config
IService::next INFO Scheduling Burnin_Panel_31_43 file to run...
IService::next INFO Writing results to /home/data/output//BurnInHybrids_PROD_v2//GPC2328_X_007_C_H2/1/
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for GPC2328_X_002_A_H0
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0004170
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.