The information on this page was generated on Tue Mar 31 11:37:24 2026 (probably UTC). You may click the button below to manually regenerate the content.
Basic Information for GPC2328_X_020_A_H0
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2328_X_020_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_020_A_H0/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2003462_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2328_X_020_A_H0.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
KA
Date
2025-08-27T23:39:59.190+00:00
Program
ASIC-X-PPB.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.676
Volume per glue dot [nL]
782.224
Weight of glue under ASICs [mg]
43.800
Weights of bare hybrid [g]
2.977
Weights of stuffed hybrid [g]
3.021
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 442.204250 +/- 3.219500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 37.893750 +/- 11.138700 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 404.310500
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 104.310500 +/- 12.626789 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 405.310500 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 435.777000 +/- 1.901250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 31.664444 +/- 6.526333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 404.112556
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 104.112556 +/- 8.438470 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 405.112556 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 432.041500 +/- 2.343250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 31.001778 +/- 8.986500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 401.039722
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 101.039722 +/- 10.547417 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 402.039722 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 428.846250 +/- 3.463000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 33.622333 +/- 7.710667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 395.223917
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 95.223917 +/- 9.820731 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 396.223917 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 427.737750 +/- 2.768250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 34.383667 +/- 5.454000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 393.354083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 93.354083 +/- 7.899957 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 394.354083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 425.403750 +/- 2.666000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 36.469556 +/- 5.168833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 388.934194
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 88.934194 +/- 7.669706 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 389.934194 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 425.090000 +/- 1.969750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 40.314556 +/- 6.949333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 384.775444
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.775444 +/- 8.784825 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.775444 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 425.149750 +/- 2.328000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 34.195667 +/- 6.642833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 390.954083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.954083 +/- 8.634050 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.954083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 427.592750 +/- 3.370000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 38.587667 +/- 9.110333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 389.005083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 89.005083 +/- 10.924975 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 390.005083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 433.081250 +/- 2.811750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 46.530625 +/- 11.001521 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 386.550625
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 86.550625 +/- 12.407232 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 387.550625 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 439.494500 +/- 0.459500 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 51.559625 +/- 4.165566 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 387.934875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.934875 +/- 6.524039 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.934875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 1008.075000, chip thickness 300.000000 and glue 104.310500, giving hybrid 603.764500 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 1000.435302, chip thickness 300.000000 and glue 104.112556, giving hybrid 596.322746 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 996.252014, chip thickness 300.000000 and glue 101.039722, giving hybrid 595.212292 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 992.285928, chip thickness 300.000000 and glue 95.223917, giving hybrid 597.062011 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 991.011656, chip thickness 300.000000 and glue 93.354083, giving hybrid 597.657572 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 988.170870, chip thickness 300.000000 and glue 88.934194, giving hybrid 599.236676 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 985.829544, chip thickness 300.000000 and glue 84.775444, giving hybrid 601.054100 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 982.266774, chip thickness 300.000000 and glue 90.954083, giving hybrid 591.312690 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 980.873272, chip thickness 300.000000 and glue 89.005083, giving hybrid 591.868189 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 983.788619, chip thickness 300.000000 and glue 86.550625, giving hybrid 597.237994 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 983.250000, chip thickness 300.000000 and glue 87.934875, giving hybrid 595.315125 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H0/1//Data__GPC2328_X_020_A_H0.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H0/1//Results__GPC2328_X_020_A_H0.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H0/1//Data__GPC2328_X_020_A_H0.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H0/1//Results__GPC2328_X_020_A_H0.txt
IService::log INFO Logging status 0111 for component GPC2328_X_020_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_020_A_H0/MetrologyHybrid_PROD_X_v2_thick_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2328_X_020_A_H0.txt...
IService::install INFO Installed Results__GPC2328_X_020_A_H0.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2328_X_020_A_H0.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H1-1.config
IService::next INFO Scheduling GPC2328-020-A0-1-4-5-6_GPC2328-016-A0.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2328_X_020_A_H1/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0004548
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2328_X_020_A_H0
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2328_X_020_A_H0
IService::install INFO Installing output directory to /home/data/modules/GPC2328_X_020_A_H0/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2328_X_020_A_H0.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2328_X_020_A_H1-1.config
IService::next INFO Scheduling HybridBonding_GPC2328_X_020_A_H1-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2328_X_020_A_H1/1/