Results for GPC2336_X_014_C_H6


The information on this page was generated on Sat Dec 27 12:11:26 2025 (probably UTC).
You may click the button below to manually regenerate the content.

Basic Information for GPC2336_X_014_C_H6


Brief description of DB components associated to this Hybrid Assembly and associated tests


Click for packaging sticker
MetadataValue
Alt Identifier UCSC-X-0743
Serial Number 20USBHX2003793
Batch PRESERIES_UCSC
Assembled True
Completed False
Current Location SCIPP, UC Santa Cruz
Manufacture ID GPC2336_X_014_C_H6
User SCIPP Module Institute Account

Children

ComponentTypeTimestamp
STAR Hybrid Flex X 2025-09-23T21:55:04.921Z
HCC Chip HCCSTARV1 2025-09-29T17:16:04.394Z
ABC Chip ABCSTARV1 2025-09-29T17:16:06.432Z
ABC Chip ABCSTARV1 2025-09-29T17:16:08.202Z
ABC Chip ABCSTARV1 2025-09-29T17:16:10.007Z
ABC Chip ABCSTARV1 2025-09-29T17:16:11.747Z
ABC Chip ABCSTARV1 2025-09-29T17:16:13.623Z
ABC Chip ABCSTARV1 2025-09-29T17:16:15.328Z
ABC Chip ABCSTARV1 2025-09-29T17:16:17.088Z
ABC Chip ABCSTARV1 2025-09-29T17:16:18.899Z
ABC Chip ABCSTARV1 2025-09-29T17:16:20.629Z
ABC Chip ABCSTARV1 2025-09-29T17:16:22.403Z
Hybrid Interposer 2025-09-23T21:55:01.829Z

Parents

ComponentTypeTimestamp
STAR Hybrid Test Panel
Module 2025-12-16T23:59:09.202Z

NameCurrent StageTimestamp

Test NamePassed?Date
Glue weight (ASICs on hybrid) 2025-09-23T22:38:57.631Z
Visual Inspection 2025-09-26T22:53:09.706Z
ASIC Metrology 2025-09-26T20:52:12.120Z
Wire bonding 2025-09-26T22:53:09.706Z
Pedestal Trim Burn In 2025-09-30T12:19:51.000Z
Strobe Delay Burn In 2025-09-30T12:19:59.000Z
Response Curve Burn In 2025-09-30T12:21:38.000Z
Noise Occupancy Burn In 2025-09-30T12:28:28.000Z

Glue weight for GPC2336_X_014_C_H6


Shown below are results for the glue weight measurements

IService::UPLOADDB                         INFO                Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB                    INFO                Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component GPC2336_X_014_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2336_X_014_C_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed 20USBHX2003793_image.jpg...
IService::install                          INFO                Installed DB_COMMENTS.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2336_X_014_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!

MetadataValue
Component type
Operator QFP, LM
Date 2025-09-23T22:38:57.631+00:00
Program ASIC_X_PPB.SRC
FieldWeight/Volume
Assummed density of glue 1.077
Total volume of ASIC glue [uL] 41.047
Volume per glue dot [nL] 789.368
Weight of glue under ASICs [mg] 44.200
Weights of bare hybrid [g] 3.320
Weights of stuffed hybrid [g] 3.364

Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               397.583500 +/- 16.528750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_0] Height in z :                               18.434375 +/- 5.302947 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             379.149125
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 79.149125 +/- 18.064352 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 380.149125 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               375.319250 +/- 2.570000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_1] Height in z :                               9.084889 +/- 8.864167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             366.234361
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 66.234361 +/- 10.496588 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 367.234361 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               372.957750 +/- 2.918250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_2] Height in z :                               -1.557556 +/- 7.032667 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             374.515306
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 74.515306 +/- 9.109039 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 375.515306 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               368.243500 +/- 3.696250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_3] Height in z :                               3.613889 +/- 7.910167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             364.629611
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 64.629611 +/- 10.061461 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 365.629611 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               366.569250 +/- 4.971250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_4] Height in z :                               16.752333 +/- 7.689500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             349.816917
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 49.816917 +/- 10.432724 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 350.816917 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               367.326250 +/- 2.589000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_5] Height in z :                               22.972111 +/- 8.530167 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             344.354139
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 44.354139 +/- 10.220894 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 345.354139 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               367.742750 +/- 1.985000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_6] Height in z :                               25.077000 +/- 7.799333 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             342.665750
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 42.665750 +/- 9.474694 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 343.665750 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               368.271250 +/- 2.689750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_7] Height in z :                               27.293667 +/- 8.046000 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             340.977583
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 40.977583 +/- 9.847480 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 341.977583 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               373.711250 +/- 5.742500 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_8] Height in z :                               30.820556 +/- 6.428833 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             342.890694
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 42.890694 +/- 9.965250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 343.890694 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               388.675500 +/- 13.101750 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [ABC_X_9] Height in z :                               33.881250 +/- 10.192591 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             354.794250
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 54.794250 +/- 17.336227 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 355.794250 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeGlueHeights           INFO                Printing associated surfaces...
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               399.614250 +/- 4.771250 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> [HCC_X_0] Height in z :                               44.821375 +/- 3.691805 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Difference in heights :                             354.792875
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 54.792875 +/- 7.835448 um 
MetrologySvc::analyzeGlueHeights           INFO                 ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 355.792875 um 
MetrologySvc::analyzeGlueHeights           INFO                --------------------------------------------------------------------------------- 
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1025.787750, chip thickness 300.000000 and glue 79.149125, giving hybrid 646.638625 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 999.073383, chip thickness 300.000000 and glue 66.234361, giving hybrid 632.839022 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 996.638455, chip thickness 300.000000 and glue 74.515306, giving hybrid 622.123149 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 991.553671, chip thickness 300.000000 and glue 64.629611, giving hybrid 626.924060 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 990.094833, chip thickness 300.000000 and glue 49.816917, giving hybrid 640.277917 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 990.794928, chip thickness 300.000000 and glue 44.354139, giving hybrid 646.440790 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 989.577099, chip thickness 300.000000 and glue 42.665750, giving hybrid 646.911349 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 986.849400, chip thickness 300.000000 and glue 40.977583, giving hybrid 645.871817 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 988.835173, chip thickness 300.000000 and glue 42.890694, giving hybrid 645.944478 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1001.610972, chip thickness 300.000000 and glue 54.794250, giving hybrid 646.816722 thickness
MetrologySvc::analyzeHybridThickness       INFO                Total stack up 1011.363250, chip thickness 300.000000 and glue 54.792875, giving hybrid 656.570375 thickness
IService::UPLOADDB                         INFO                Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB                     INFO                Doing DB upload...
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2336_X_014_C_H6/4//Data__GPC2336_X_014_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2336_X_014_C_H6/4//Results__GPC2336_X_014_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2336_X_014_C_H6/4//Data__GPC2336_X_014_C_H6.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2336_X_014_C_H6/4//Results__GPC2336_X_014_C_H6.txt
IService::log                              INFO                Logging status 0111 for component GPC2336_X_014_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2336_X_014_C_H6/MetrologyHybrid_PROD_X_v2_thick_interposer-4/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed HybridThickness.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Tilt.pdf...
IService::install                          INFO                Installed Data__GPC2336_X_014_C_H6.txt...
IService::install                          INFO                Installed Results__GPC2336_X_014_C_H6.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install                          INFO                Installed GPC2336_X_014_C_H6.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2337_X_023_C_H5-4.config
IService::next                             INFO                Scheduling GPC2336-014-C4-C5-C6_GPC2337-023-C5_run4.txt file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_thick_interposer//GPC2337_X_023_C_H5/4/
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0004967
MetadataValue
Component type X
Operator LM
Date 2025-09-26T20:52:12.120+00:00
Program version MetrologyHybrid_PROD_X_v2_thick_interposer/PROD_clonable_v2_new-jig_DB102_6hybrids_thick_interposer
Instrument SmartScope Flash 250

The thickness of the glue \(t_{glue}\) is calculated as: $$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$ where \(t_{chip}\) is the thickness of the chip \(z_{i}\) is the z-height measurement, \(N_{i}\) is the number of measurements on a given surface, and \(c\) and \(b\) run over measurements taken on the chip and base, respectively. The assumed thickness of the chip is \(t_{chip} = 300\mu m\).

Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface. On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as: $$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$ where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively. In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed. The total uncertainty is calculated as: $$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$ The glue thickness measurements for each ASIC are shown in the figure and table below.


The thickness total stack up is measured from the top of the each chip to the jig, and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.


The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds. These measured positions are compared against the technical drawns to calculated the relative ASIC position. In some cases, the SmartScope incorrectly measures a different object than these square pads, and using properties (such as the perimeter), the position is corrected. The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.

The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.

The tilt of a chip can be calculated in either the direction along the surface of a chip. We define the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be: $$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$

Wirebonding for GPC2336_X_014_C_H6


Wirebonding summaries will be given below

WireBondSvc::run                           INFO                Loading group FAILED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run                           INFO                Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run                           INFO                Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB                         INFO                Working on test code WIRE_BONDING
IService::UPLOADDB                         INFO                Working on test code VISUAL_INSPECTION
IService::log                              INFO                Logging status 0111 for component GPC2336_X_014_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2336_X_014_C_H6/HybridBonding_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install                          INFO                Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install                          INFO                Installed GPC2336_X_014_C_H6.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//HybridBonding_v1//GPC2337_X_023_C_H4-1.config
IService::next                             INFO                Scheduling HybridBonding_GPC2337_X_023_C_H4-1.json file to run...
IService::next                             INFO                Writing results to /home/data/output//HybridBonding_v1//GPC2337_X_023_C_H4/1/
MetadataValue
Date 2025-09-26T22:53:09.706+00:00
Operator LM
Bonder hk1
Version v1
Bond numberTypeComment

Electrical results


Electrical summaries will be given below

ElectricalSvc::getListOfFilesFromDir       INFO                Scanning for test files GPC2336_X_014_C_H6/20USBHX2003793
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Scanning for test files GPC2336_X_014_C_H6/20USBHX2003793
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2003793_20250929_4_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2003793_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2003793_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2003793_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir   INFO                Loading json fle SN20USBHX2003793_20250929_4_3PG_BURNIN.json
ElectricalSvc::read                        INFO                Found 0 results files...
ElectricalSvc::load_asic_db                INFO                Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2336_X_014_C_H6_GAIN_TEST.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
IService::UPLOADDB                         INFO                Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB                         INFO                Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB                         INFO                Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB                         INFO                Working on test code NO_BURNIN
IService::log                              INFO                Logging status 0111 for component GPC2336_X_014_C_H6
IService::install                          INFO                Installing output directory to /home/data/modules/GPC2336_X_014_C_H6/BurnInHybrids_PROD_v2-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003793_20250929_4_PEDESTAL_TRIM_BURNIN.json...
IService::install                          INFO                Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003793_20250929_4_STROBE_DELAY_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_RESPONSE_CURVE_BURNIN.json...
IService::install                          INFO                Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_3PG_BURNIN.json...
IService::install                          INFO                Installed DB_READY_NO_BURNIN_SN20USBHX2003793_20250929_4_NO_BURNIN.json...
IService::install                          INFO                Installed GPC2336_X_014_C_H6.root...
IService::install                          INFO                Installed status.json...
TopControl::monitor                        INFO                Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor                        INFO                Service with algoirthm name TCModules_PROD_v0 ignored through users request!
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003785_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003785_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003785_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003785_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003785_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003785_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003785_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003785_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003785_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003785_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003787_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003787_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003787_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003787_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003787_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003787_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003787_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003787_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003787_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003787_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003793_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003793_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003793_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003793_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003793_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003793_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003793_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003793_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003793_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003793_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003786_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003786_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003786_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003786_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003786_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003786_20250929_4_NO_BURNIN.json
ElectricalSvc::PassFail                    INFO                Reading PassFail status directly from uploaded files
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2003786_20250929_4_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2003786_20250929_4_STROBE_DELAY_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2003786_20250929_4_3PG_BURNIN.json
ElectricalSvc::PassFail                    INFO                Loading json fle DB_READY_NO_BURNIN_SN20USBHX2003786_20250929_4_NO_BURNIN.json
ElectricalSvc::load_asic_db                WARNING             Could not find database ASIC GAIN_TEST results for GPC2336_X_014_C_H6
MetaData::getLocalName                     WARNING             Could not find a local name for identifier 20USBHN0004967

Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.