The information on this page was generated on Wed Apr 1 11:56:55 2026 (probably UTC). You may click the button below to manually regenerate the content.
Basic Information for GPC2349_X_008_B_H2
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2349_X_008_B_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2349_X_008_B_H2/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2004661_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2349_X_008_B_H2.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
AS
Date
2026-01-21T23:27:18.179+00:00
Program
ASIC_X_PPB.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.118
Volume per glue dot [nL]
771.509
Weight of glue under ASICs [mg]
43.200
Weights of bare hybrid [g]
2.570
Weights of stuffed hybrid [g]
2.613
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 457.721500 +/- 6.015000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 73.564500 +/- 15.533015 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 384.157000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 84.157000 +/- 17.391227 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 385.157000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 458.645000 +/- 0.510250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 88.211111 +/- 10.679167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 370.433889
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 70.433889 +/- 11.802752 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 371.433889 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 455.280500 +/- 1.334750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 75.233444 +/- 11.553333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 380.047056
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 80.047056 +/- 12.659426 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 381.047056 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 451.690500 +/- 1.539500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 73.000000 +/- 11.119500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 378.690500
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 78.690500 +/- 12.288749 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 379.690500 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 450.868500 +/- 1.098000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 84.158333 +/- 7.677167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 366.710167
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 66.710167 +/- 9.227377 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 367.710167 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 448.047250 +/- 1.127750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 76.738778 +/- 6.785333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 371.308472
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 71.308472 +/- 8.503680 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 372.308472 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 446.837250 +/- 1.205750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 67.024333 +/- 9.706333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 379.812917
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 79.812917 +/- 10.984841 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 380.812917 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 445.765750 +/- 0.953500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 61.779667 +/- 10.563000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.986083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.986083 +/- 11.725448 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.986083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 447.082500 +/- 1.995750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 56.750889 +/- 9.615167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 390.331611
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 90.331611 +/- 11.019730 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 391.331611 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 450.348250 +/- 1.094500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 56.268125 +/- 7.724258 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 394.080125
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 94.080125 +/- 9.266180 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 395.080125 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 449.548750 +/- 0.863000 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 70.440750 +/- 2.624780 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 379.108000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 79.108000 +/- 5.712639 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 380.108000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 943.149250, chip thickness 300.000000 and glue 84.157000, giving hybrid 558.992250 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 939.483711, chip thickness 300.000000 and glue 70.433889, giving hybrid 569.049822 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 937.476817, chip thickness 300.000000 and glue 80.047056, giving hybrid 557.429762 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.940149, chip thickness 300.000000 and glue 78.690500, giving hybrid 556.249649 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.782585, chip thickness 300.000000 and glue 66.710167, giving hybrid 569.072418 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.299989, chip thickness 300.000000 and glue 71.308472, giving hybrid 562.991517 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 932.877108, chip thickness 300.000000 and glue 79.812917, giving hybrid 553.064192 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.995383, chip thickness 300.000000 and glue 83.986083, giving hybrid 546.009300 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.296208, chip thickness 300.000000 and glue 90.331611, giving hybrid 538.964597 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.815194, chip thickness 300.000000 and glue 94.080125, giving hybrid 537.735069 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.172750, chip thickness 300.000000 and glue 79.108000, giving hybrid 552.064750 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H2/1//Data__GPC2349_X_008_B_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H2/1//Results__GPC2349_X_008_B_H2.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H2/1//Data__GPC2349_X_008_B_H2.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H2/1//Results__GPC2349_X_008_B_H2.txt
IService::log INFO Logging status 0111 for component GPC2349_X_008_B_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2349_X_008_B_H2/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2349_X_008_B_H2.txt...
IService::install INFO Installed Results__GPC2349_X_008_B_H2.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2349_X_008_B_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H3-1.config
IService::next INFO Scheduling GPC2349-011-C4-5-6_GPC2349-008-B1-2-3.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2349_X_008_B_H3/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0006846
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2349_X_008_B_H2
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2349_X_008_B_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2349_X_008_B_H2/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2349_X_008_B_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2349_X_008_B_H3-1.config
IService::next INFO Scheduling HybridBonding_GPC2349_X_008_B_H3-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2349_X_008_B_H3/1/
Metadata
Value
Date
2026-01-28T21:44:54.509+00:00
Operator
LM, KA
Bonder
hk1
Version
v1
Bond number
Type
Comment
Electrical results
Electrical summaries will be given below
ElectricalSvc::getListOfFilesFromDir INFO Scanning for test files GPC2349_X_008_B_H2/20USBHX2004661
ElectricalSvc::getListOfJsonFilesFromDir INFO Scanning for test files GPC2349_X_008_B_H2/20USBHX2004661
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2004661_20260130_6_PEDESTAL_TRIM_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2004661_20260130_6_NO_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2004661_20260130_6_3PG_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2004661_20260130_6_RESPONSE_CURVE_BURNIN.json
ElectricalSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2004661_20260130_6_STROBE_DELAY_BURNIN.json
ElectricalSvc::read INFO Found 0 results files...
ElectricalSvc::load_asic_db INFO Reading ASIC database file /home/data/upload//BurnInHybrids_PROD_v2//GPC2349_X_008_B_H2_GAIN_TEST.json
ElectricalSvc::PassFail INFO Reading PassFail status directly from uploaded files
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_BURNIN
IService::UPLOADDB INFO Working on test code STROBE_DELAY_BURNIN
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_BURNIN
IService::UPLOADDB INFO Working on test code NO_BURNIN
IService::log INFO Logging status 0111 for component GPC2349_X_008_B_H2
IService::install INFO Installing output directory to /home/data/modules/GPC2349_X_008_B_H2/BurnInHybrids_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_BURNIN_SN20USBHX2004661_20260130_6_PEDESTAL_TRIM_BURNIN.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_BURNIN_SN20USBHX2004661_20260130_6_STROBE_DELAY_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2004661_20260130_6_3PG_BURNIN.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_BURNIN_SN20USBHX2004661_20260130_6_RESPONSE_CURVE_BURNIN.json...
IService::install INFO Installed DB_READY_NO_BURNIN_SN20USBHX2004661_20260130_6_NO_BURNIN.json...
IService::install INFO Installed GPC2349_X_008_B_H2.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//BurnInHybrids_PROD_v2//GPC2349_X_008_B_H3-1.config
IService::next INFO Scheduling Burnin_Panel_60_Jan30th file to run...
IService::next INFO Writing results to /home/data/output//BurnInHybrids_PROD_v2//GPC2349_X_008_B_H3/1/
ElectricalSvc::load_asic_db WARNING Could not find database ASIC GAIN_TEST results for GPC2349_X_008_B_H2
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0006846
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.