The information on this page was generated on Wed Apr 1 12:02:19 2026 (probably UTC). You may click the button below to manually regenerate the content.
Basic Information for GPC2414_X_023_A_H1
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2414_X_023_A_H1
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H1/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2004886_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2414_X_023_A_H1.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
IService::log INFO Logging status 1111 for component GPC2414_X_023_A_H3
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H3/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO File already installed: warningLog.txt...
IService::install INFO File already installed: errorLog.txt...
IService::install INFO File already installed: infoLog.txt...
IService::install INFO File already installed: 20USBHX2004888_image.jpg...
IService::install INFO File already installed: DB_COMMENTS.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO File already installed: status.json...
IService::install INFO File already installed: GPC2414_X_023_A_H3.root...
IService::log INFO Logging status 1111 for component GPC2414_X_023_A_H5
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H5/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO File already installed: warningLog.txt...
IService::install INFO File already installed: errorLog.txt...
IService::install INFO File already installed: infoLog.txt...
IService::install INFO File already installed: 20USBHX2004890_image.jpg...
IService::install INFO File already installed: DB_COMMENTS.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO File already installed: status.json...
IService::install INFO File already installed: GPC2414_X_023_A_H5.root...
IService::log INFO Logging status 1111 for component GPC2414_X_023_A_H6
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO File already installed: warningLog.txt...
IService::install INFO File already installed: errorLog.txt...
IService::install INFO File already installed: infoLog.txt...
IService::install INFO File already installed: 20USBHX2004891_image.jpg...
IService::install INFO File already installed: DB_COMMENTS.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO File already installed: DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO File already installed: status.json...
IService::install INFO File already installed: GPC2414_X_023_A_H6.root...
Metadata
Value
Component type
Operator
LM, AS
Date
2026-02-05T23:05:52.004+00:00
Program
ASIC_X_PPB.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
40.397
Volume per glue dot [nL]
776.867
Weight of glue under ASICs [mg]
43.500
Weights of bare hybrid [g]
2.453
Weights of stuffed hybrid [g]
2.497
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 443.610500 +/- 7.705500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 60.193375 +/- 8.736128 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.417125
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.417125 +/- 12.676540 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.417125 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 443.365250 +/- 1.416500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 60.952444 +/- 9.868000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 382.412806
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 82.412806 +/- 11.152753 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 383.412806 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 439.261750 +/- 2.193500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 51.263778 +/- 8.061167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 387.997972
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 87.997972 +/- 9.736213 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 388.997972 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 434.214250 +/- 2.798250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 54.156111 +/- 6.697000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 380.058139
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 80.058139 +/- 8.813626 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 381.058139 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 433.388000 +/- 2.084250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 50.143000 +/- 7.424500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.245000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.245000 +/- 9.190609 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.245000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 429.817000 +/- 1.662750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 41.405667 +/- 7.482167 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 388.411333
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 88.411333 +/- 9.151369 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 389.411333 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 429.504250 +/- 1.661750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 44.225667 +/- 9.942000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 385.278583
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 85.278583 +/- 11.251879 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 386.278583 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 429.883750 +/- 2.034500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 36.690556 +/- 10.271500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 393.193194
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 93.193194 +/- 11.603573 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 394.193194 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 431.355750 +/- 3.314500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 33.817667 +/- 8.237000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 397.538083
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 97.538083 +/- 10.189901 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 398.538083 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 436.280000 +/- 2.318750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 41.393125 +/- 9.155795 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 394.886875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 94.886875 +/- 10.686683 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 395.886875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 439.243000 +/- 0.529250 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 33.244125 +/- 5.194053 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 405.998875
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 105.998875 +/- 7.228990 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 406.998875 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 946.799500, chip thickness 300.000000 and glue 83.417125, giving hybrid 563.382375 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 941.354184, chip thickness 300.000000 and glue 82.412806, giving hybrid 558.941379 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 938.627627, chip thickness 300.000000 and glue 87.997972, giving hybrid 550.629655 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.657827, chip thickness 300.000000 and glue 80.058139, giving hybrid 554.599688 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.485949, chip thickness 300.000000 and glue 83.245000, giving hybrid 552.240949 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 933.228893, chip thickness 300.000000 and glue 88.411333, giving hybrid 544.817560 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 932.725657, chip thickness 300.000000 and glue 85.278583, giving hybrid 547.447074 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.320643, chip thickness 300.000000 and glue 93.193194, giving hybrid 538.127448 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 930.803914, chip thickness 300.000000 and glue 97.538083, giving hybrid 533.265830 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 934.980973, chip thickness 300.000000 and glue 94.886875, giving hybrid 540.094098 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 929.782000, chip thickness 300.000000 and glue 105.998875, giving hybrid 523.783125 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H1/1//Data__GPC2414_X_023_A_H1.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H1/1//Results__GPC2414_X_023_A_H1.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H1/1//Data__GPC2414_X_023_A_H1.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H1/1//Results__GPC2414_X_023_A_H1.txt
IService::log INFO Logging status 0111 for component GPC2414_X_023_A_H1
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H1/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2414_X_023_A_H1.txt...
IService::install INFO Installed Results__GPC2414_X_023_A_H1.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2414_X_023_A_H1.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H2-1.config
IService::next INFO Scheduling GPC2414-023-A1-2-3-4-5-6.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2414_X_023_A_H2/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0008182
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2414_X_023_A_H1
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2414_X_023_A_H1
IService::install INFO Installing output directory to /home/data/modules/GPC2414_X_023_A_H1/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2414_X_023_A_H1.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2414_X_023_A_H2-1.config
IService::next INFO Scheduling HybridBonding_GPC2414_X_023_A_H2-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2414_X_023_A_H2/1/