The information on this page was generated on Sat May 23 05:25:08 2026 (America/Los_Angeles). You may click the button below to manually regenerate the content.
Basic Information for GPC2536_X_005_B_H6
Brief description of DB components associated to this Hybrid Assembly and associated tests
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code ASIC_GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for ASIC_GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2536_X_005_B_H6
IService::install INFO Installing output directory to /home/data/modules/GPC2536_X_005_B_H6/GlueWeightHybridASIC_PROD_v2-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2004843_image.jpg...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2536_X_005_B_H6.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_LS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
Metadata
Value
Component type
Operator
LM, FMM
Date
2026-02-04T20:56:34.938+00:00
Program
ASIC_X_PPB.SRC
Field
Weight/Volume
Assummed density of glue
1.077
Total volume of ASIC glue [uL]
38.447
Volume per glue dot [nL]
739.363
Weight of glue under ASICs [mg]
41.400
Weights of bare hybrid [g]
2.453
Weights of stuffed hybrid [g]
2.494
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 423.859500 +/- 7.803500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 28.314500 +/- 12.958969 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 395.545000
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 95.545000 +/- 15.932027 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 396.545000 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 425.362750 +/- 2.143000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 29.790000 +/- 9.065833 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 395.572750
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 95.572750 +/- 10.572690 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 396.572750 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 421.995250 +/- 2.774500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 36.310778 +/- 9.688333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 385.684472
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 85.684472 +/- 11.249962 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 386.684472 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 416.983750 +/- 3.675000 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 28.255556 +/- 8.496500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 388.728194
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 88.728194 +/- 10.521223 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 389.728194 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 416.972250 +/- 2.693250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 33.662778 +/- 10.646000 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 383.309472
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 83.309472 +/- 12.066106 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 384.309472 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 414.427250 +/- 2.964250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 41.071444 +/- 8.733667 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 373.355806
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 73.355806 +/- 10.491125 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 374.355806 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 414.137750 +/- 2.457500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 38.310556 +/- 13.825500 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 375.827194
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 75.827194 +/- 14.905830 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 376.827194 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 414.851750 +/- 2.498250 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 36.630444 +/- 13.533333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 378.221306
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 78.221306 +/- 14.642143 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 379.221306 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 416.226000 +/- 3.615500 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 42.900556 +/- 12.936333 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 373.325444
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 73.325444 +/- 14.332500 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 374.325444 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 421.495000 +/- 3.431750 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 43.745500 +/- 9.063695 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 377.749500
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 77.749500 +/- 10.905387 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 378.749500 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 429.682000 +/- 0.372750 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 52.259875 +/- 6.129555 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 377.422125
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 300.000000 +/- 5.000000 extra material : 77.422125 +/- 7.918989 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 378.422125 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeHybridThickness INFO Total stack up 943.045000, chip thickness 300.000000 and glue 95.545000, giving hybrid 547.500000 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 938.104740, chip thickness 300.000000 and glue 95.572750, giving hybrid 542.531990 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 935.719140, chip thickness 300.000000 and glue 85.684472, giving hybrid 550.034668 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.430194, chip thickness 300.000000 and glue 88.728194, giving hybrid 542.702000 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 932.727293, chip thickness 300.000000 and glue 83.309472, giving hybrid 549.417820 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 931.162512, chip thickness 300.000000 and glue 73.355806, giving hybrid 557.806706 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 930.327459, chip thickness 300.000000 and glue 75.827194, giving hybrid 554.500264 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 928.891444, chip thickness 300.000000 and glue 78.221306, giving hybrid 550.670139 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 927.918072, chip thickness 300.000000 and glue 73.325444, giving hybrid 554.592627 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 932.083116, chip thickness 300.000000 and glue 77.749500, giving hybrid 554.333616 thickness
MetrologySvc::analyzeHybridThickness INFO Total stack up 933.648750, chip thickness 300.000000 and glue 77.422125, giving hybrid 556.226625 thickness
IService::UPLOADDB INFO Working on test code ASIC_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_005_B_H6/1//Data__GPC2536_X_005_B_H6.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_005_B_H6/1//Results__GPC2536_X_005_B_H6.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_005_B_H6/1//Data__GPC2536_X_005_B_H6.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_005_B_H6/1//Results__GPC2536_X_005_B_H6.txt
IService::log INFO Logging status 0111 for component GPC2536_X_005_B_H6
IService::install INFO Installing output directory to /home/data/modules/GPC2536_X_005_B_H6/MetrologyHybrid_PROD_X_v2_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed HybridThickness.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Tilt.pdf...
IService::install INFO Installed Data__GPC2536_X_005_B_H6.txt...
IService::install INFO Installed Results__GPC2536_X_005_B_H6.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_ASIC_METROLOGY.json...
IService::install INFO Installed GPC2536_X_005_B_H6.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_024_B_H0-1.config
IService::next INFO Scheduling GPC2536-005-B5-6_GPC2536-024-B0-1-2-3.txt file to run...
IService::next INFO Writing results to /home/data/output//MetrologyHybrid_PROD_X_v2_interposer//GPC2536_X_024_B_H0/1/
MetaData::getLocalName WARNING Could not find a local name for identifier 20USBHN0009038
Measurement::addPoint ERROR Unknown type ?! Ignoring!
The thickness of the glue \(t_{glue}\) is calculated as:
$$t_{glue} = \frac{1}{N_{c}}\sum_{c=1}^{N_{c}} z_{c} - \frac{1}{N_{b}}\sum_{b=1}^{N_{b}} z_{b} - t_{chip} $$
where \(t_{chip}\) is the thickness of the chip
\(z_{i}\) is the z-height measurement,
\(N_{i}\) is the number of measurements on a given surface,
and \(c\) and \(b\) run over measurements taken on the chip and base, respectively.
The assumed thickness of the chip is \(t_{chip} = 300\mu m\).
Uncertainties on the glue height measurement are estimated from the spread in z-height measurements on a given surface.
On a given surface, the height uncertainty \(\sigma_{i}\) is calculated as:
$$\sigma_{i} = \frac{\Delta z}{2\sqrt{N_{i}}}$$
where \(\Delta z = z_{max} - z_{min}\) and \(z_{max}\) and \(z_{min}\) are the maximum and minimum z-height measurements, respectively.
In addition, a conservative \(\sigma_{chip} = 10\mu m\) uncertainty on the chip thickeness is assumed.
The total uncertainty is calculated as:
$$\sigma_{glue} = \sqrt{ \sigma_{c}^2 + \sigma_{b}^2 + \sigma_{chip} }$$
The glue thickness measurements for each ASIC are shown in the figure and table below.
The thickness total stack up is measured from the top of the each chip to the jig,
and accounts for the combined thickness of hybrid flex, glue, and ABC/HCC chips in the case of hybrid.
The positions of the ASICs are measured on the 95x95 \(\mu m^2\) square pads on the opposite side of the sensor wire bonds.
These measured positions are compared against the technical drawns to calculated the relative ASIC position.
In some cases, the SmartScope incorrectly measures a different object than these square pads,
and using properties (such as the perimeter), the position is corrected.
The positions are shown in the figure below. If any corrections are applied, they are shown as transparent points.
The hybrid thickness is plotted below. It is calculated from the total stack up height minus the assembed chip thickness and measured glue thickness.
The tilt of a chip can be calculated in either the direction along the surface of a chip. We define
the x-direction to be any points whose difference is much larger along x, and similarly for y. The tilt in both cases is defined to be:
$$tilt = \frac{|\Delta z|}{\sqrt{\Delta x^{2} + \Delta y^{2}}} $$
Wirebonding for GPC2536_X_005_B_H6
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_ASIC_BACKEND
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PANEL
WireBondSvc::run INFO Loading group REPAIRED_ASIC_BACKEND
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PANEL
IService::UPLOADDB INFO Working on test code WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component GPC2536_X_005_B_H6
IService::install INFO Installing output directory to /home/data/modules/GPC2536_X_005_B_H6/HybridBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_HYBRID_ASSEMBLY_VISUAL_INSPECTION.json...
IService::install INFO Installed GPC2536_X_005_B_H6.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//HybridBonding_v1//GPC2536_X_024_B_H0-1.config
IService::next INFO Scheduling HybridBonding_GPC2536_X_024_B_H0-1.json file to run...
IService::next INFO Writing results to /home/data/output//HybridBonding_v1//GPC2536_X_024_B_H0/1/