Module LS results


The module name column is highlighted in GREEN once the component has succesfully reached BNL

Modules with stage BONDED are ready for thermal cycling:

Based on the stage FINISHED, the following 15 modules are ready to ship: SCIPP-LS-0003, SCIPP-LS-0004, SCIPP-LS-0006, SCIPP-LS-0014, SCIPP-LS-0015, SCIPP-LS-0016, SCIPP-LS-0017, SCIPP-LS-0018, SCIPP-LS-0019, SCIPP-LS-0020, SCIPP-LS-0021, SCIPP-LS-0022, SCIPP-LS-0023, SCIPP-LS-0034, SCIPP-LS-0002

The box colours reflect the test status.

As an extra check, the following text may be present in the boxes if the local test results are not consistent with the results from the database:

Module Stage Flags Post HV-tab IV Gluing Metrology Wirebonding TC Electrical Shipped Comment
SCIPP-LS-0105                
SCIPP-LS-0104                
SCIPP-LS-0103                
SCIPP-LS-0102            
SCIPP-LS-0101 FAILED            
SCIPP-LS-0100 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0099 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0098 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0097 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0096 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0095 FAILED              
SCIPP-LS-0094 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0093 FINISHED   ANL  
SCIPP-LS-0092 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0091 FAILED   BNL  
SCIPP-LS-0090 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0089 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0088 FAILED            
SCIPP-LS-0087 BONDED        
SCIPP-LS-0086 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0085 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0084 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0083 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0082 ON_CORE   CERN_TRANSIT  
SCIPP-LS-0081 ON_CORE   BNL  
SCIPP-LS-0080 ON_CORE   BNL  
SCIPP-LS-0079 ON_CORE   BNL Strange smear/scratch/defect in top right of sensor. Examine before proceeding. - KA, AND, 26.06.2023--21-35-11
SCIPP-LS-0078 ON_CORE   BNL  
SCIPP-LS-0077 ON_CORE   BNL  
SCIPP-LS-0076 ON_CORE   BNL Small scuff on top right of sensor found before tabbing - KA, AND, 26.06.2023--21-16-26
SCIPP-LS-0075 ON_CORE   BNL  
SCIPP-LS-0074 ON_CORE   BNL  
SCIPP-LS-0073 ON_CORE   BNL  
SCIPP-LS-0072 ON_CORE   BNL  
SCIPP-LS-0071 ON_CORE   BNL  
SCIPP-LS-0070 ON_CORE   BNL  
SCIPP-LS-0069 FAILED             wrong shims used for hybrid gluing, no powerboard attached. set aside for special tests. - , 29.10.2024--17-30-52
SCIPP-LS-0068 FAILED           wrong shims used for hybrid gluing, no powerboard attached. set aside for special tests. - , 29.10.2024--17-30-35
SCIPP-LS-0067 ON_CORE   BNL  
SCIPP-LS-0066 ON_CORE   BNL Small wire tail on ground bond tilted onto adjacent channel, touched glass layer, now removed - FMM, AND, 23.06.2023--21-58-53
SCIPP-LS-0065 ON_CORE   RAL  
SCIPP-LS-0064 ON_CORE   RAL  
SCIPP-LS-0063 ON_CORE   RAL  
SCIPP-LS-0062 ON_CORE   RAL  
SCIPP-LS-0061 ON_CORE   RAL  
SCIPP-LS-0060 ON_CORE   RAL  
SCIPP-LS-0059 ON_CORE   RAL  
SCIPP-LS-0058 ON_CORE   RAL  
SCIPP-LS-0057 ON_CORE   RAL  
SCIPP-LS-0056 ON_CORE   RAL  
SCIPP-LS-0055 ON_CORE   RAL  
SCIPP-LS-0054 ON_CORE   RAL  
SCIPP-LS-0053 ON_CORE   RAL  
SCIPP-LS-0052 QA              
SCIPP-LS-0051 ON_CORE   RAL  
SCIPP-LS-0050 AT_LOADING_SITE   RAL  
SCIPP-LS-0049 GLUED   BNL  
SCIPP-LS-0048 FINISHED   BNL  
SCIPP-LS-0047 ON_CORE   BNL Suction cup mark in center of sensor - NN, AND, 23.06.2023--17-27-11
SCIPP-LS-0046 ON_CORE   BNL  
SCIPP-LS-0045 ON_CORE   BNL  
SCIPP-LS-0044 ON_CORE   BNL  
SCIPP-LS-0043 ON_CORE   BNL  
SCIPP-LS-0042 ON_CORE   BNL  
SCIPP-LS-0041 ON_CORE   BNL  
SCIPP-LS-0040 FINISHED   BNL During assembly, the vacuum hose for the pickup tool flopped over onto the sensor and left a smudge. - KA, 23.02.2024--19-37-36
SCIPP-LS-0039 ON_CORE   BNL  
SCIPP-LS-0038 ON_CORE   BNL  
SCIPP-LS-0037 ON_CORE   BNL  
SCIPP-LS-0036 ON_CORE   BNL  
SCIPP-LS-0035 ON_CORE   BNL  
SCIPP-LS-0034 FINISHED      
SCIPP-LS-0033 ON_CORE   BNL  
SCIPP-LS-0032 ON_CORE   BNL  
SCIPP-LS-0031 AT_LOADING_SITE   RAL back of sensor scratched when placing the tab; not deep; probably will be fine. IV test to confirm. - AND, KA, 12.06.2023--19-12-35
SCIPP-LS-0030 AT_LOADING_SITE   RAL  
SCIPP-LS-0029 AT_LOADING_SITE   RAL  
SCIPP-LS-0028 AT_LOADING_SITE   RAL  
SCIPP-LS-0027 AT_LOADING_SITE   RAL  
SCIPP-LS-0026 FINISHED     LBNL_STRIP_MODULES Guard ring covered in glue under the powerboard :( - Kirsten Affolder, 17.11.2023--23-15-48
SCIPP-LS-0025 TESTED   RAL  
SCIPP-LS-0024 TESTED   RAL  
SCIPP-LS-0023 FINISHED      
SCIPP-LS-0022 FINISHED      
SCIPP-LS-0021 FINISHED      
SCIPP-LS-0020 FINISHED ! DB MISSING    
SCIPP-LS-0019 FINISHED ! DB MISSING    
SCIPP-LS-0018 FINISHED ! DB MISSING    
SCIPP-LS-0017 FINISHED ! DB MISSING    
SCIPP-LS-0016 FINISHED      
SCIPP-LS-0015 FINISHED      
SCIPP-LS-0014 FINISHED      
SCIPP-LS-0013 FINISHED   BNL  
SCIPP-LS-0012 FINISHED   BNL large suction cup mark on front center of sensor (it was there before tabbing). - NN, KA, 09.06.2023--21-55-00
SCIPP-LS-0011 FINISHED   BNL  
SCIPP-LS-0010 FINISHED   UPENN  
SCIPP-LS-0009 FAILED        
SCIPP-LS-0008 FINISHED   BNL  
SCIPP-LS-0007 FINISHED   BNL  
SCIPP-LS-0006 FINISHED      
SCIPP-LS-0005 FINISHED   BNL  
SCIPP-LS-0004 FINISHED      
SCIPP-LS-0003 FINISHED      
SCIPP-LS-0002 FINISHED      
SCIPP-LS-0001 FINISHED   UCSC test1 - SCIPP Stripper, 07.07.2025--19-33-13
test1 - SCIPP Stripper, 07.07.2025--19-36-13
asdf - SCIPP Stripper, 07.07.2025--19-40-41
test2 - SCIPP Stripper, 07.07.2025--19-37-14
asdf - SCIPP Stripper, 07.07.2025--19-44-38
asdf3 - SCIPP Stripper, 07.07.2025--19-45-34
asdf4 - SCIPP Stripper, 07.07.2025--19-47-09