Shown below are the results of the module metrology scans
IService::UPLOADDB INFO Working on test code MMETROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Data__SCIPP-M4-01.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Results__SCIPP-M4-01.txt
IService::UPLOADDB INFO Working on test code MMETROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Data__SCIPP-M4-01.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Results__SCIPP-M4-01.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Data__SCIPP-M4-01.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M4-01/1//Results__SCIPP-M4-01.txt
IService::log INFO Logging status 0111 for component SCIPP-M4-01
IService::install INFO Installing output directory to /home/data/modules/SCIPP-M4-01/HybridToSensorMetrology_v2a-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed Data__SCIPP-M4-01.txt...
IService::install INFO Installed Results__SCIPP-M4-01.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_MODULE_MMETROLOGY.json...
IService::install INFO Installed SCIPP-M4-01.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//MetrologyModules///SCIPP-M3-09.config
IService::next INFO Scheduling SCIPP-M3-09.txt file to run...
IService::next INFO Writing results to /home/data/output//HybridToSensorMetrology_v2a//SCIPP-M3-09/1/
✔ Component is at UCSC. OK to upload
✔ Current stage GLUED is equal to one of the required stages. OK to upload
Metadata
Value
Component type
LS
Operator
Matthew Gignac
Date
10.03.2020 00:00
Program version
v2a
Instrument
SmartScope Flash 250
The glue thicknesses are shown below.
Comments for SCIPP-M4-01
Vitaliy Fadeyev 23.03.2020--19-45-20
Start of test: HV: 300 V, 1.10 uA, LV: 11.0 V, 0.314 A, 5.0 % RH, 20.9 C. End of test: 1.22uA, 4.8%RH, 21.1C
Matthew Gignac 10.03.2020--22-37-14
Module metrology was performed with a slight variant of the v2a program. Had some issues with finding the edge of the sensor; so the first few steps were performed in edit mode to adjust lighting. On a second repeat, issues did not appear again.