Results for SCIPP-PPB-SS-012


Metrology results


Shown below are the results of the module metrology scans

MetrologySvc::PassFail_Module              INFO                Thickness group ABC_X
MetrologySvc::PassFail_Module              INFO                 >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module              INFO                 >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_0 point with z=126.953000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_1 point with z=146.307167 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_2 point with z=147.066833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_3 point with z=150.463333 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_4 point with z=150.893167 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_5 point with z=150.278167 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_6 point with z=152.004833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_7 point with z=150.661500 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_8 point with z=144.707500 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_X_9 point with z=118.268000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Average value 143.760350 is within allowed range!
MetrologySvc::PassFail_Module              INFO                Thickness group ABC_Y
MetrologySvc::PassFail_Module              INFO                 >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module              INFO                 >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_0 point with z=112.479167 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_1 point with z=132.063333 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_2 point with z=135.013500 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_3 point with z=133.831833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_4 point with z=135.796000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_5 point with z=136.866833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_6 point with z=133.708333 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_7 point with z=126.706333 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_8 point with z=120.193167 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement ABC_Y_9 point with z=94.826000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Average value 126.148450 is within allowed range!
MetrologySvc::PassFail_Module              INFO                Thickness group PB
MetrologySvc::PassFail_Module              INFO                 >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module              INFO                 >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module              INFO                 >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module              INFO                Including measurement PB_1 point with z=111.488833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement PB_2 point with z=91.954000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement PB_3 point with z=104.258000 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Including measurement PB_4 point with z=123.557833 for module glue height calculation
MetrologySvc::PassFail_Module              INFO                Average value 107.814667 is within allowed range!
MetrologySvc::writeOutput                  INFO                Writing common output file /home/data/output//MetrologyModules_PPB_SS_v1//SCIPP-PPB-SS-012/1//Data__SCIPP-PPB-SS-012.txt
MetrologySvc::writeOutput                  INFO                Writing results output file /home/data/output//MetrologyModules_PPB_SS_v1//SCIPP-PPB-SS-012/1//Results__SCIPP-PPB-SS-012.txt
IService::log                              INFO                Logging status 0111 for component SCIPP-PPB-SS-012
IService::install                          INFO                Installing output directory to /home/data/modules/SCIPP-PPB-SS-012/MetrologyModules_PPB_SS_v1-1/
IService::install                          INFO                Installed warningLog.txt...
IService::install                          INFO                Installed errorLog.txt...
IService::install                          INFO                Installed infoLog.txt...
IService::install                          INFO                Installed Summary.pdf...
IService::install                          INFO                Installed TotalStackUp.pdf...
IService::install                          INFO                Installed Positions.pdf...
IService::install                          INFO                Installed Data__SCIPP-PPB-SS-012.txt...
IService::install                          INFO                Installed Results__SCIPP-PPB-SS-012.txt...
IService::install                          INFO                Installed Results.json...
IService::install                          INFO                Installed SCIPP-PPB-SS-012.root...
IService::install                          INFO                Installed status.json...
MetaData::readField                        INFO                Reading file /home/data/upload//MetrologyModules_PPB_SS_v1//SCIPP-PPB_SS-012.config
IService::next                             INFO                Scheduling SCIPP-PPB_SS-012.PRT file to run...
IService::next                             INFO                Writing results to /home/data/output//MetrologyModules_PPB_SS_v1//SCIPP-PPB_SS-012/1/
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Chip
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Base
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Chip
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Base
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Chip
MeasurementBase::addUncertaintyComponent   WARNING             Unknown uncertainty component Base
IService::UPLOADDB                         ERROR               Serial number missing for SCIPP-PPB-SS-012. Likely local cache isn't updated or component not in DB!
  • ✘ Component is at . Prohibiting upload!
  • ✘ Component fails stage checks. Current stage is but requires one of { "GLUED" }. Prohibiting upload!

MetadataValue
Component type SS
Operator Tony Affolder
Date 2022-05-19T16:30:32.707+00:00
Program version v1
Instrument SmartScope Flash 250

The glue thicknesses are shown below.


The positions are defined as the hybrid cross fiducials and the circles on the powerboard

.

Height of components on the powerboard

.