SensorIVSvc::read INFO Using measurement with voltage 700.360000 and current 0.082520 for current stability calculation
SensorIVSvc::read INFO Using measurement with voltage 700.380000 and current 0.080620 for current stability calculation
SensorIVSvc::read INFO Using measurement with voltage 700.380000 and current 0.081020 for current stability calculation
SensorIVSvc::read INFO Using measurement with voltage 700.380000 and current 0.081620 for current stability calculation
SensorIVSvc::CalculateVBD INFO Average voltage 5.000000, current 0.015455, dIdV 0.002662
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.861096 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 14.969999, current 0.033420, dIdV 0.000944
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.422801 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 24.959999, current 0.038685, dIdV 0.000111
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.071618 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 34.980000, current 0.040595, dIdV 0.000270
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.232586 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 45.009998, current 0.040755, dIdV -0.000239
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.263426 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 55.020000, current 0.039015, dIdV -0.000109
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.153715 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 65.019997, current 0.038775, dIdV 0.000061
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.102288 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 75.029999, current 0.039735, dIdV 0.000131
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.246868 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 85.070000, current 0.040295, dIdV -0.000019
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.039873 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 95.089996, current 0.040110, dIdV -0.000018
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.042759 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 105.070000, current 0.041275, dIdV 0.000252
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.640228 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 115.070000, current 0.041935, dIdV -0.000119
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.325885 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 125.080002, current 0.041845, dIdV 0.000101
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.301902 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 135.089996, current 0.042855, dIdV 0.000101
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.317743 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 145.089996, current 0.043320, dIdV -0.000008
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.026848 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 155.100006, current 0.043430, dIdV 0.000030
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.106711 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 165.119995, current 0.043340, dIdV -0.000048
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.182874 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 175.130005, current 0.043655, dIdV 0.000111
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.444408 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 185.139999, current 0.044465, dIdV 0.000051
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.212350 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 195.160004, current 0.045625, dIdV 0.000180
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.771139 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 205.179993, current 0.047485, dIdV 0.000191
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.825300 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 215.190002, current 0.048745, dIdV 0.000061
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.268754 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 225.209991, current 0.050305, dIdV 0.000250
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.121457 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 235.220001, current 0.052420, dIdV 0.000172
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.771802 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 245.250000, current 0.052980, dIdV -0.000060
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.276090 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 255.270004, current 0.053240, dIdV 0.000112
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.538083 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 265.260010, current 0.053705, dIdV -0.000019
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.093845 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 275.250000, current 0.053065, dIdV -0.000109
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.566520 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 285.260010, current 0.052575, dIdV 0.000011
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.059446 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 295.279999, current 0.052485, dIdV -0.000029
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.163154 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 305.290009, current 0.053245, dIdV 0.000181
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.035725 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 315.320007, current 0.053055, dIdV -0.000218
SensorIVSvc::CalculateVBD INFO V_avg_BD -1.296390 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 325.350006, current 0.053365, dIdV 0.000280
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.709751 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 335.179993, current 0.054490, dIdV -0.000058
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.357332 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 345.010010, current 0.054165, dIdV -0.000009
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.057212 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 355.010010, current 0.054125, dIdV 0.000001
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.006572 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 365.000000, current 0.054685, dIdV 0.000111
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.740880 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 375.010010, current 0.056045, dIdV 0.000161
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.075138 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 385.029999, current 0.056860, dIdV 0.000002
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.013516 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 395.050018, current 0.056425, dIdV -0.000089
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.621875 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 405.070007, current 0.056235, dIdV 0.000051
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.366628 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 415.079987, current 0.057645, dIdV 0.000231
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.663344 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 425.070007, current 0.058005, dIdV -0.000159
SensorIVSvc::CalculateVBD INFO V_avg_BD -1.167513 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 435.059998, current 0.058365, dIdV 0.000231
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.721903 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 445.049988, current 0.059380, dIdV -0.000028
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.210279 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 455.070007, current 0.058995, dIdV -0.000049
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.375717 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 465.110016, current 0.059155, dIdV 0.000081
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.635597 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 475.119995, current 0.060165, dIdV 0.000121
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.955531 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 485.119995, current 0.061175, dIdV 0.000081
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.642333 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 495.139984, current 0.063685, dIdV 0.000419
SensorIVSvc::CalculateVBD INFO V_avg_BD 3.260162 and VBD limit 5.500000
SensorIVSvc::CalculateVBD INFO Average voltage 505.149994, current 0.065195, dIdV -0.000119
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.923895 and VBD limit 5.551500
SensorIVSvc::CalculateVBD INFO Average voltage 515.160034, current 0.064455, dIdV -0.000029
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.230861 and VBD limit 5.651600
SensorIVSvc::CalculateVBD INFO Average voltage 525.179993, current 0.065070, dIdV 0.000152
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.226792 and VBD limit 5.751800
SensorIVSvc::CalculateVBD INFO Average voltage 535.169983, current 0.066085, dIdV 0.000051
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.413836 and VBD limit 5.851700
SensorIVSvc::CalculateVBD INFO Average voltage 545.179993, current 0.066195, dIdV -0.000029
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.237892 and VBD limit 5.951800
SensorIVSvc::CalculateVBD INFO Average voltage 555.190002, current 0.067155, dIdV 0.000221
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.830733 and VBD limit 6.051900
SensorIVSvc::CalculateVBD INFO Average voltage 565.179993, current 0.068915, dIdV 0.000131
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.074346 and VBD limit 6.151800
SensorIVSvc::CalculateVBD INFO Average voltage 575.190002, current 0.069825, dIdV 0.000051
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.419279 and VBD limit 6.251900
SensorIVSvc::CalculateVBD INFO Average voltage 585.200012, current 0.070240, dIdV 0.000032
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.266606 and VBD limit 6.352000
SensorIVSvc::CalculateVBD INFO Average voltage 595.200012, current 0.069855, dIdV -0.000109
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.928735 and VBD limit 6.452000
SensorIVSvc::CalculateVBD INFO Average voltage 605.220032, current 0.070665, dIdV 0.000270
SensorIVSvc::CalculateVBD INFO V_avg_BD 2.311769 and VBD limit 6.552200
SensorIVSvc::CalculateVBD INFO Average voltage 615.260010, current 0.072475, dIdV 0.000091
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.769446 and VBD limit 6.652600
SensorIVSvc::CalculateVBD INFO Average voltage 625.270020, current 0.073635, dIdV 0.000141
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.199698 and VBD limit 6.752700
SensorIVSvc::CalculateVBD INFO Average voltage 635.270020, current 0.074545, dIdV 0.000041
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.348703 and VBD limit 6.852700
SensorIVSvc::CalculateVBD INFO Average voltage 645.290039, current 0.074955, dIdV 0.000041
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.352266 and VBD limit 6.952900
SensorIVSvc::CalculateVBD INFO Average voltage 655.309998, current 0.075615, dIdV 0.000091
SensorIVSvc::CalculateVBD INFO V_avg_BD 0.787068 and VBD limit 7.053100
SensorIVSvc::CalculateVBD INFO Average voltage 665.320007, current 0.077330, dIdV 0.000252
SensorIVSvc::CalculateVBD INFO V_avg_BD 2.168119 and VBD limit 7.153200
SensorIVSvc::CalculateVBD INFO Average voltage 675.330017, current 0.079195, dIdV 0.000121
SensorIVSvc::CalculateVBD INFO V_avg_BD 1.029760 and VBD limit 7.253300
SensorIVSvc::CalculateVBD INFO Average voltage 685.350037, current 0.081305, dIdV 0.000300
SensorIVSvc::CalculateVBD INFO V_avg_BD 2.532176 and VBD limit 7.353500
SensorIVSvc::CalculateVBD INFO Average voltage 695.359985, current 0.082665, dIdV -0.000029
SensorIVSvc::CalculateVBD INFO V_avg_BD -0.243942 and VBD limit 7.453600
SensorIVSvc::CalculateVBD INFO Calculated VBD to be 690.359985
SensorIVSvc::read INFO Mean voltage for current stability 0.081445 calculated with 4 points
SensorIVSvc::read INFO RMS current stability 0.008785
IService::UPLOADDB INFO Working on test code MODULE_IV_PS_V1
SensorIVSvc::uploadDB INFO Formatting database upload for MODULE_IV_PS_V1 and run number 1
SensorIVSvc::writeOutput INFO Writing results output file /home/data/output//SensorIV_PostTabIV_PPB_v1//SCIPP-PS_LS-0119/1//20USBML1236246-HV_TAB_ATTACHED_IV_001.dat
SensorIVSvc::getDate INFO Parsing date 2025-07-10T23:37:37.974+00:00...
SensorIVSvc::getDate INFO Year 2025
SensorIVSvc::getDate INFO Month 7
SensorIVSvc::getDate INFO Day 10
SensorIVSvc::getDate INFO Hour 23
SensorIVSvc::getDate INFO Minute 37
SensorIVSvc::getDate INFO Second 37
SensorIVSvc::getDate INFO Offset 0:0
SensorIVSvc::getDate INFO Converted month into string Jul
SensorIVSvc::getDate INFO FINALLY obtained 10 Jul 2025
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
SensorIVSvc::uploadDB INFO Formatting database upload for VISUAL_INSPECTION and run number 1
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/SensorIV_PostTabIV_PPB_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed IVCurve.pdf...
IService::install INFO Installed 20USBML1236246-HV_TAB_ATTACHED_IV_001.dat...
IService::install INFO Installed DB_READY_MODULE_MODULE_IV_PS_V1.json...
IService::install INFO Installed DB_READY_MODULE_VISUAL_INSPECTION.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//SensorIV_PostTabIV_PPB_v1//SCIPP-PS_LS-0118-1.config
IService::next INFO Scheduling Data_SCIPP-PS_LS-0118-1.txt file to run...
IService::next INFO Writing results to /home/data/output//SensorIV_PostTabIV_PPB_v1//SCIPP-PS_LS-0118/1/
Metadata
Value
Component type
ATLAS18LS
Operator
tate
Date
2025-07-10T23:37:37.974+00:00
Institute
UCSC
Power supply
CAEN_DT1415ET
Temperarture [C]
18.7
Humidity
1.2
Current per area @500V
0.771
Breakdown voltage
690.360
Current stability (RMS@700V)
0.009
The current measurements are calibrated to a common temperature using the following relationship:
$$I_{temp}^{SF} = \left ( \frac{T_{ref}}{T_{meas}} \right )^{2} \times e^{eE_{g}^{Si} \frac{T_{ref}-T_{meas}}{2 k_{B} T_{ref} T_{meas} }} $$
where \( T_{ref} \) is the reference temperature,
\( T_{meas} \) is the temperatured measured during the test,
\( e \) is the electric charge,
\( E_{g}^{Si} \) is the band gap energy of silicon, and
\( k_{B} \) is the Boltzman constant
Glue weight for SCIPP-PS_LS-0119
Shown below are results for the glue weight measurements
IService::UPLOADDB INFO Working on test code GLUE_WEIGHT
GlueWeightSvc::uploadDB INFO Formatting database test for GLUE_WEIGHT
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/GlueWeightModule_LS_PPA-2/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_COMMENTS.json...
IService::install INFO Installed DB_READY_MODULE_GLUE_WEIGHT.json...
IService::install INFO Installed DB_READY_MODULE_VISUAL_INSPECTION.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name GlueWeightModule_SS_PPA ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleBonding_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPullTest ignored through users request!
TopControl::monitor INFO Service with algoirthm name PullTestCicorelCard ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridFlexArray_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Powerboards_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ABC_Wafer_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HCC_PullTest_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorBondingQC_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_Before_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HVTabSheet_SheerTest_After_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name PhotoUpload ignored through users request!
TopControl::monitor INFO Service with algoirthm name PictureModule ignored through users request!
TopControl::monitor INFO Service with algoirthm name GeneralPictures ignored through users request!
TopControl::monitor INFO Service with algoirthm name PreHVTabIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PreTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name Module_postHVTabIV_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_PostTabIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalIV ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_Module_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SensorIV_AMACIV_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name SixWayJig_Y_slots ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridPanelMetrology_v7 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridMetrology_Y_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_v10-beta ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_Y_v0_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyHybrid_PROD_X_v2_thick_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name HybridToSensorMetrology_v2a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_v8a ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPA_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_SS_wuerth_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PPB_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
✘ Component is at BNL. Prohibiting upload!
✘ Component fails stage checks. Current stage is ON_CORE but requires one of { "GLUED" }. Prohibiting upload!
Metadata
Value
Operator
FMM, KA
Date
2025-07-22T16:04:57.355+00:00
X-hybrid program
LS_Hybrid.src
Powerboard program
LS_PB.src
Gluing method
Dispenser
Field
Weight/Volume
Weight bare sensor [g]
7.151
Weight of x-hybrid [g]
3.352
Weight of x-tabs [g]
0.211
Weight of back-end wirebonds
0.000
Weights of powerboard [g]
2.405
Weight of stuffed module [g]
12.952
Weight of glue [mg]
255.100
Metrology results
Shown below are the results of the module metrology scans
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : 689.833000 +/- 15.677755 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_0] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 689.930050
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 109.930050 +/- 18.623421 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 690.930050 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : 713.687333 +/- 6.153731 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_1] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 713.784383
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 133.784383 +/- 11.785932 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 714.784383 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : 716.147667 +/- 5.986553 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_2] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 716.244717
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 136.244717 +/- 11.699513 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 717.244717 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : 723.893167 +/- 7.527282 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_3] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 723.990217
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 143.990217 +/- 12.557857 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 724.990217 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : 734.579333 +/- 5.587694 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_4] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 734.676383
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 154.676383 +/- 11.500527 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 735.676383 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : 734.080167 +/- 6.511764 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_5] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 734.177217
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 154.177217 +/- 11.976764 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 735.177217 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : 730.752667 +/- 7.206399 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_6] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 730.849717
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 150.849717 +/- 12.368184 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 731.849717 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : 726.248333 +/- 10.132518 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_7] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 726.345383
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 146.345383 +/- 14.272621 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 727.345383 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : 719.933000 +/- 8.341737 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_8] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 720.030050
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 140.030050 +/- 13.062327 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 721.030050 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : 700.723667 +/- 16.330136 um
MetrologySvc::analyzeGlueHeights INFO ----> [ABC_X_9] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 700.820717
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 120.820717 +/- 19.175848 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 701.820717 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : 745.546333 +/- 0.986980 um
MetrologySvc::analyzeGlueHeights INFO ----> [HCC_X_0] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 745.643383
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 165.643383 +/- 10.100194 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 746.643383 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_0] Height in z : 674.720667 +/- 15.836429 um
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_0] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 674.817717
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 94.817717 +/- 18.757193 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 675.817717 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_1] Height in z : 669.048250 +/- 18.651250 um
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_1] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 669.145300
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 89.145300 +/- 21.187471 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 670.145300 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_2] Height in z : 635.322000 +/- 10.685798 um
MetrologySvc::analyzeGlueHeights INFO ----> [H_X_2] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 635.419050
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 580.000000 +/- 10.000000 extra material : 55.419050 +/- 14.670585 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 636.419050 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [PB_1] Height in z : 646.900600 +/- 6.559282 um
MetrologySvc::analyzeGlueHeights INFO ----> [PB_1] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 646.997650
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 545.000000 +/- 15.000000 extra material : 101.997650 +/- 16.403170 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 647.997650 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [PB_2] Height in z : 673.877000 +/- 0.000000 um
MetrologySvc::analyzeGlueHeights INFO ----> [PB_2] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 673.974050
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 545.000000 +/- 15.000000 extra material : 128.974050 +/- 15.034620 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 674.974050 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [PB_3] Height in z : 641.092750 +/- 9.025500 um
MetrologySvc::analyzeGlueHeights INFO ----> [PB_3] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 641.189800
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 545.000000 +/- 15.000000 extra material : 96.189800 +/- 17.535662 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 642.189800 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [PB_4] Height in z : 608.964500 +/- 22.133750 um
MetrologySvc::analyzeGlueHeights INFO ----> [PB_4] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 609.061550
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 545.000000 +/- 15.000000 extra material : 64.061550 +/- 26.757105 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 610.061550 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeGlueHeights INFO Printing associated surfaces...
MetrologySvc::analyzeGlueHeights INFO ----> [PB_5] Height in z : 597.661000 +/- 10.229007 um
MetrologySvc::analyzeGlueHeights INFO ----> [PB_5] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeGlueHeights INFO ----> Difference in heights : 597.758050
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue assuming 545.000000 +/- 15.000000 extra material : 52.758050 +/- 18.184399 um
MetrologySvc::analyzeGlueHeights INFO ----> Thickeness of glue using derived value -1.000000 from hybrid measurements : 598.758050 um
MetrologySvc::analyzeGlueHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO Printing associated surfaces for total height
MetrologySvc::analyzeTotalHeights INFO ----> [C1] Height in z : 3093.135000 +/- 0.000000 um
MetrologySvc::analyzeTotalHeights INFO ----> [C1] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeTotalHeights INFO ----> Difference in heights : 3093.232050
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO Printing associated surfaces for total height
MetrologySvc::analyzeTotalHeights INFO ----> [C2] Height in z : 3169.376000 +/- 0.000000 um
MetrologySvc::analyzeTotalHeights INFO ----> [C2] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeTotalHeights INFO ----> Difference in heights : 3169.473050
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO Printing associated surfaces for total height
MetrologySvc::analyzeTotalHeights INFO ----> [C3] Height in z : 3116.019000 +/- 0.000000 um
MetrologySvc::analyzeTotalHeights INFO ----> [C3] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeTotalHeights INFO ----> Difference in heights : 3116.116050
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO Printing associated surfaces for total height
MetrologySvc::analyzeTotalHeights INFO ----> [C4] Height in z : 3105.036000 +/- 0.000000 um
MetrologySvc::analyzeTotalHeights INFO ----> [C4] Height in z : -0.097050 +/- 1.019703 um
MetrologySvc::analyzeTotalHeights INFO ----> Difference in heights : 3105.133050
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::analyzeTotalHeights INFO Printing associated surfaces for total height
MetrologySvc::analyzeTotalHeights INFO ----> [Shield] Height in z : 5798.457400 +/- 14.577151 um
MetrologySvc::analyzeTotalHeights INFO ----> [Shield] Height in z : 16.818525 +/- 38.806624 um
MetrologySvc::analyzeTotalHeights INFO ----> Difference in heights : 5781.638875
MetrologySvc::analyzeTotalHeights INFO ----> [Shield] Max height in z (shieldbox) : 5820.866000 +/- 14.577151 um
MetrologySvc::analyzeTotalHeights INFO ----> [Shield] Height in z : 16.818525 +/- 38.806624 um
MetrologySvc::analyzeTotalHeights INFO ----> Max difference in heights (shieldbox) : 5804.047475
MetrologySvc::analyzeTotalHeights INFO ---------------------------------------------------------------------------------
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
IService::UPLOADDB INFO Working on test code MODULE_METROLOGY
MetrologySvc::uploadDB INFO Doing DB upload...
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyModules_PROD_LS_v1_interposer//SCIPP-PS_LS-0119/1//Data__SCIPP-PS_LS-0119.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyModules_PROD_LS_v1_interposer//SCIPP-PS_LS-0119/1//Results__SCIPP-PS_LS-0119.txt
MetrologySvc::writeOutput INFO Writing common output file /home/data/output//MetrologyModules_PROD_LS_v1_interposer//SCIPP-PS_LS-0119/1//Data__SCIPP-PS_LS-0119.txt
MetrologySvc::writeOutput INFO Writing results output file /home/data/output//MetrologyModules_PROD_LS_v1_interposer//SCIPP-PS_LS-0119/1//Results__SCIPP-PS_LS-0119.txt
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/MetrologyModules_PROD_LS_v1_interposer-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed Summary.pdf...
IService::install INFO Installed TotalStackUp.pdf...
IService::install INFO Installed Positions.pdf...
IService::install INFO Installed Data__SCIPP-PS_LS-0119.txt...
IService::install INFO Installed Results__SCIPP-PS_LS-0119.txt...
IService::install INFO Installed Results.json...
IService::install INFO Installed DB_READY_MODULE_MODULE_METROLOGY.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_LS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin ignored through users request!
TopControl::monitor INFO Service with algoirthm name MetrologyModules_PROD_SS_v1_thin_interposer ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleLS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ModuleSS_Bow_PPA_v0 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PPB_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name BurnInHybrids_PROD_v2 ignored through users request!
TopControl::monitor INFO Service with algoirthm name ElectricalModules_PPA_v1 ignored through users request!
TopControl::monitor INFO Service with algoirthm name TCModules_PROD_v0 ignored through users request!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
Metadata
Value
Component type
Operator
FMM
Date
2025-07-17T13:58:15.393+00:00
Program version
PROD_v1
Instrument
SmartScope Flash 250
The glue thicknesses are shown below.
The positions are defined as the hybrid cross fiducials and the circles on the powerboard
.
Height of components on the powerboard
.
Wirebonding for SCIPP-PS_LS-0119
Wirebonding summaries will be given below
WireBondSvc::run INFO Loading group FAILED_HYBRID_TO_PB
WireBondSvc::run INFO Loading group FAILED_MODULE_TO_FRAME
WireBondSvc::run INFO Loading group FAILED_ROW_1
WireBondSvc::run INFO Loading group FAILED_ROW_2
WireBondSvc::run INFO Loading group FAILED_ROW_3
WireBondSvc::run INFO Loading group FAILED_ROW_4
WireBondSvc::run INFO Loading group REPAIRED_HYBRID_TO_PB
WireBondSvc::run INFO Loading group REPAIRED_MODULE_TO_FRAME
WireBondSvc::run INFO Loading group REPAIRED_ROW_1
WireBondSvc::run INFO Loading group REPAIRED_ROW_2
WireBondSvc::run INFO Loading group REPAIRED_ROW_3
WireBondSvc::run INFO Loading group REPAIRED_ROW_4
IService::UPLOADDB INFO Working on test code MODULE_WIRE_BONDING
IService::UPLOADDB INFO Working on test code VISUAL_INSPECTION
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/ModuleBonding_v1-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed DB_READY_MODULE_MODULE_WIRE_BONDING.json...
IService::install INFO Installed DB_READY_MODULE_VISUAL_INSPECTION.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//ModuleBonding_v1//SCIPP-PS_LS-0120-1.config
IService::next INFO Scheduling ModuleBonding_SCIPP-PS_LS-0120-1.json file to run...
IService::next INFO Writing results to /home/data/output//ModuleBonding_v1//SCIPP-PS_LS-0120/1/
Metadata
Value
Date
2025-07-18T18:41:22.685+00:00
Operator
QFP
Bonder
hk2
Version
v1
Bond number
Type
Comment
Thermal cycling results
Thermal cycling summaries will be given below
TCSvc::getListOfFilesFromDir INFO Scanning for test files 500-9492/20USBP05009492
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files 500-9492/20USBP05009492
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files GPC2328_X_014_B_H4/20USBHX2002922
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files GPC2328_X_014_B_H4/20USBHX2002922
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_RESPONSE_CURVE_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_PEDESTAL_TRIM_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_3PG_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_OPEN_CHANNEL_SEARCH_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_STROBE_DELAY_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_NO_TC.json
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files VPA38893-W02341/20USBSL0002341
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files VPA38893-W02341/20USBSL0002341
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files SCIPP-PS_LS-0119/20USBML1236246
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files SCIPP-PS_LS-0119/20USBML1236246
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_20250721_13_MODULE_IV_AMAC_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_20250721_13_MODULE_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_TESTED_20250722_13_432_HVSTABILITY.json
TCSvc::read INFO Found 0 results files...
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_TC
IService::UPLOADDB INFO Working on test code STROBE_DELAY_TC
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_TC
IService::UPLOADDB INFO Working on test code NO_TC
IService::UPLOADDB INFO Working on test code MODULE_IV_AMAC_TC
IService::UPLOADDB INFO Working on test code HVSTABILITY
IService::UPLOADDB INFO Working on test code OPEN_CHANNEL_SEARCH_TC
IService::UPLOADDB INFO Working on test code MODULE_TC
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/TCModules_PROD_v0-1/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2002922_TC_Noise.pdf...
IService::install INFO Installed 20USBHX2002922_TC_Averages_RC_innse.pdf...
IService::install INFO Installed 20USBHX2002922_TC_Averages_RC_gain.pdf...
IService::install INFO Installed 20USBML1236246_TC_AMAC_IV_fast.pdf...
IService::install INFO Installed 20USBML1236246_TC_AMAC_IV.pdf...
IService::install INFO Installed 20USBML1236246_TC_ENV_DATA.pdf...
IService::install INFO Installed 20USBML1236246_TC_HV_STABILITY.pdf...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_TC_SN20USBHX2002922_20250721_13_PEDESTAL_TRIM_TC.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_TC_SN20USBHX2002922_20250721_13_STROBE_DELAY_TC.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_TC_SN20USBHX2002922_20250721_13_RESPONSE_CURVE_TC.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_TC_SN20USBHX2002922_20250721_13_3PG_TC.json...
IService::install INFO Installed DB_READY_NO_TC_SN20USBHX2002922_20250721_13_NO_TC.json...
IService::install INFO Installed DB_READY_MODULE_IV_AMAC_TC_SN20USBML1236246_20250721_13_MODULE_IV_AMAC_TC.json...
IService::install INFO Installed DB_READY_HVSTABILITY_SN20USBML1236246_TESTED_20250722_13_432_HVSTABILITY.json...
IService::install INFO Installed DB_READY_OPEN_CHANNEL_SEARCH_TC_SN20USBHX2002922_20250721_13_OPEN_CHANNEL_SEARCH_TC.json...
IService::install INFO Installed DB_READY_MODULE_TC_SN20USBML1236246_20250721_13_MODULE_TC.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
MetrologySvc::PassFail_Module INFO Thickness group ABC_X
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_0 point with z=109.930050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_1 point with z=133.784383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_2 point with z=136.244717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_3 point with z=143.990217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_4 point with z=154.676383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_5 point with z=154.177217 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_6 point with z=150.849717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_7 point with z=146.345383 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_8 point with z=140.030050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement ABC_X_9 point with z=120.820717 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 139.084883 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group PB
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 170.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 40.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 70.000000
MetrologySvc::PassFail_Module INFO Including measurement PB_1 point with z=101.997650 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_2 point with z=128.974050 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_3 point with z=96.189800 for module glue height calculation
MetrologySvc::PassFail_Module INFO Including measurement PB_4 point with z=64.061550 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 97.805762 is within allowed range!
MetrologySvc::PassFail_Module INFO Thickness group ShieldBox
MetrologySvc::PassFail_Module INFO >>> Minimum allowed 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum allowed 6110.000000
MetrologySvc::PassFail_Module INFO >>> Minimum with problems 0.000000
MetrologySvc::PassFail_Module INFO >>> Maximum with problems 0.000000
MetrologySvc::PassFail_Module INFO Including measurement Shield point with z=5804.047475 for module glue height calculation
MetrologySvc::PassFail_Module INFO Average value 5804.047475 is within allowed range!
IService::addStageTransformation INFO Adding allow stage transformation from "STUFFED" to "BARE"
IService::addStageTransformation INFO Adding allow stage transformation from "BARE" to "SMD"
IService::addStageTransformation INFO Adding allow stage transformation from "FAILED_ELECTRICAL" to "SMD"
IService::addStageTransformation INFO Adding allow stage transformation from "SMD" to "ASIC"
IService::addStageTransformation INFO Adding allow stage transformation from "HV_TAB_ATTACHED" to "GLUED"
IService::addStageTransformation INFO Adding allow stage transformation from "HV_TAB_ATTACHED" to "GLUED"
IService::addStageTransformation INFO Adding allow stage transformation from "ASIC_ATTACHMENT" to "WIRE_BONDING"
IService::addStageTransformation INFO Adding allow stage transformation from "GLUED" to "BONDED"
IService::addStageTransformation INFO Adding allow stage transformation from "BARE" to "SMD"
IService::addStageTransformation INFO Adding allow stage transformation from "THERMAL" to "MODULE_RCP"
IService::addStageTransformation INFO Adding allow stage transformation from "BONDED" to "MODULE_RCP"
IService::addStageTransformation INFO Adding allow stage transformation from "BURN_IN" to "MODULE_RCP"
IService::addStageTransformation INFO Adding allow stage transformation from "ON_WAFER" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "PROBING" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "FAILED_VI" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_A" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_C" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_T" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_X" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_B" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "ON_WAFER" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "PROBING" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "FAILED_VI" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_A" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_C" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_T" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_X" to "BOND_PULLING"
IService::addStageTransformation INFO Adding allow stage transformation from "CATEGORY_B" to "BOND_PULLING"
IService::addFailFlag INFO Adding fail flag "FAILED_MODULE_RECEPTION"
IService::addPassFlag INFO Adding passed flag "PASSED_MODULE_RECEPTION"
IService::addStageTransformation INFO Adding allow stage transformation from "WIRE_BONDING" to "BURN_IN"
IService::addPostStageTransformation INFO Adding post stage transformation from "BURN_IN" to "FINISHED_HYBRID"
IService::addPostStageTransformation INFO Adding post stage transformation from "FINISHED_HYBRID" to "AT_MODULE_ASSEMBLY_SITE"
IService::addStageTransformation INFO Adding allow stage transformation from "WIRE_BONDING" to "BURN_IN"
IService::addPostStageTransformation INFO Adding post stage transformation from "BURN_IN" to "FINISHED_HYBRID"
IService::addPostStageTransformation INFO Adding post stage transformation from "FINISHED_HYBRID" to "AT_MODULE_ASSEMBLY_SITE"
IService::addStageTransformation INFO Adding allow stage transformation from "BONDED" to "TESTED"
IService::addStageTransformation INFO Adding allow stage transformation from "BONDED" to "TESTED"
IService::addPostStageTransformation INFO Adding post stage transformation from "TESTED" to "FINISHED"
TopControl::initialize INFO Running initialization...
IService::INITIALIZE() INFO User did not provide a MetaData object. Creating a fresh one now
MetrologySvc::setTolerenceDetailed WARNING Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setTolerenceDetailed WARNING Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setTolerenceDetailed WARNING Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 580.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_1! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_2! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_3! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_4! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_5! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_6! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_7! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_8! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_9! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_0! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_1! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_2! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_3! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_4! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_5! Overwriting 385.000000, 15.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_0! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_1! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_2! Overwriting 420.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setTolerenceDetailed WARNING Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_1! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_1! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_2! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_2! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_3! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_3! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_4! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_4! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_5! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_5! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_6! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_6! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_7! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_7! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_8! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_8! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_9! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_9! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_0! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_1! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_2! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_3! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_4! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_5! Overwriting 385.000000, 10.000000 -> 385.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_X_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_1! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_2! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_Y_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_0! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_1! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_2! Overwriting 403.000000, 10.000000 -> 370.000000 10.000000 !
MetrologySvc::setTolerenceDetailed WARNING Already have tolerance defined for HCC_X_0! Overwriting 80.000000, 160.000000 -> 80.000000 160.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_1! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_1! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_2! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_2! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_3! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_3! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_4! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_4! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_5! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_5! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_6! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_6! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_7! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_7! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_8! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_8! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_X_9! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for ABC_Y_9! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_0! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_1! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_2! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_3! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_4! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for PB_5! Overwriting 385.000000, 10.000000 -> 545.000000 15.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_X_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_1! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_X_2! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for HCC_Y_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_0! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_1! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
MetrologySvc::setExtraMatZDetailed WARNING Already have extra material defined for H_Y_2! Overwriting 403.000000, 10.000000 -> 530.000000 10.000000 !
Metadata
Value
Date
2025-07-21T12:48:14.000Z
Duration [hrs]
18.000
Max Humidity [%]
0.000
Max Temperature [C]
21.177
Min Temperature [C]
-35.051
Test Station
SCIPP_COLDBOX1
ITSDAQ Version
itsdaq_23_3_2023-2330-g8b9a82db6
User
qbl
Test Summary
Test
Passed
Problems
Open Channel Search
True
False
Pedestal Trim
True
False
Strobe Delay
True
False
3PG
True
False
Response Curve
True
False
Noise Occupancy
True
False
AMAC IV
True
False
HV Stability
True
False
Module TC
True
False
Response Curve Defect Summary
Defect #
Description
Chip Bank
Run Number
Chip #
Channel(s)
1
13-10
Strip with high gain
away
9
1279
2
13-10
Strip with high gain
under
3
385
3
13-10
Strip with high gain
under
9
1279
4
13-115
Strip with high noise
away
0
0
5
13-132
Strip with high gain
away
9
1279
6
13-132
Strip with high gain
under
9
1279
7
13-149
Strip with high noise
away
6
812
8
13-149
Strip with high gain
away
9
1279
9
13-149
Strip with high gain
under
3
385
10
13-149
Strip with high noise
under
9
1165
11
13-166
Strip with high gain
away
9
1279
12
13-166
Strip with high gain
under
3
385
13
13-166
Strip with high gain
under
9
1279
14
13-183
Strip with high noise
away
0
0
15
13-183
Strip with high noise
away
4
558
16
13-183
Strip with high gain
away
9
1279
17
13-183
Strip with high noise
under
1
230
18
13-200
Strip with high gain
away
9
1279
19
13-200
Strip with high gain
under
9
1279
20
13-217
Strip with high noise
away
0
0
21
13-217
Strip with high gain
away
9
1279
22
13-217
Strip with high noise
under
1
230
23
13-217
Strip with high gain
under
3
385
24
13-217
Strip with high noise
under
3
438
25
13-217
Strip with high noise
under
9
1165
26
13-234
Strip with high gain
away
9
1279
27
13-234
Strip with high gain
under
9
1279
28
13-251
Strip with high noise
away
0
0
29
13-251
Strip with high gain
away
9
1279
30
13-251
Strip with high noise
under
9
1165
31
13-268
Strip with high noise
away
0
0
32
13-268
Strip with high gain
away
9
1279
33
13-268
Strip with high gain
under
3
385
34
13-268
Strip with high gain
under
9
1279
35
13-285
Strip with high noise
away
4
574
36
13-285
Strip with high gain
away
9
1279
37
13-285
Strip with high noise
under
5
643
38
13-302
Strip with high gain
away
9
1279
39
13-302
Strip with high gain
under
9
1279
40
13-31
Strip with high noise
away
0
0
41
13-31
Strip with high gain
away
9
1279
42
13-319
Strip with high noise
away
0
0
43
13-319
Strip with high gain
away
9
1279
44
13-319
Strip with high gain
under
3
385
45
13-336
Strip with high noise
away
0
0
46
13-336
Strip with high gain
away
9
1279
47
13-336
Strip with high noise
under
5
640
48
13-336
Strip with high gain
under
9
1279
49
13-353
Strip with high gain
away
9
1279
50
13-353
Strip with high gain
under
3
385
51
13-353
Strip with high noise
under
9
1165
52
13-370
Strip with high gain
away
9
1279
53
13-370
Strip with high gain
under
3
385
54
13-370
Strip with high gain
under
9
1279
55
13-388
Strip with high noise
away
0
0
56
13-388
Strip with high noise
away
1
181
57
13-388
Strip with high noise
away
4
574
58
13-388
Strip with high gain
away
9
1279
59
13-404
Strip with high noise
away
0
0
60
13-404
Strip with high noise
away
4
574
61
13-404
Strip with high gain
away
9
1279
62
13-404
Strip with high noise
under
9
1165
63
13-421
Strip with high gain
away
9
1279
64
13-421
Strip with high gain
under
9
1279
65
13-47
Strip with high noise
away
0
0
66
13-47
Strip with high noise
away
1
142
67
13-47
Strip with high noise
away
4
574
68
13-47
Strip with high gain
away
9
1279
69
13-47
Strip with high noise
under
8
1079
70
13-64
Strip with high noise
away
5
640
71
13-64
Strip with high gain
away
9
1279
72
13-64
Strip with high gain
under
9
1279
73
13-81
Strip with high noise
away
0
0
74
13-81
Strip with high noise
away
4
538
75
13-81
Strip with high noise
away
4
574
76
13-81
Strip with high gain
away
9
1279
77
13-81
Strip with high noise
under
9
1165
78
13-98
Strip with high noise
away
0
0
79
13-98
Strip with high gain
away
9
1279
80
13-98
Strip with high gain
under
9
1279
Comments
Comments
13-10 - 3 defects found affecting 3 strips
13-10 - 1 maximum consecutive defects
13-10 - Cuts from: LS link 0
13-10 - Cuts from: LS link 1
13-31 - 2 defects found affecting 2 strips
13-31 - 1 maximum consecutive defects
13-31 - Cuts from: LS link 0
13-31 - Cuts from: LS link 1
13-47 - 5 defects found affecting 5 strips
13-47 - 1 maximum consecutive defects
13-47 - Cuts from: LS link 0
13-47 - Cuts from: LS link 1
13-64 - 3 defects found affecting 3 strips
13-64 - 1 maximum consecutive defects
13-64 - Cuts from: LS link 0
13-64 - Cuts from: LS link 1
13-81 - 5 defects found affecting 5 strips
13-81 - 1 maximum consecutive defects
13-81 - Cuts from: LS link 0
13-81 - Cuts from: LS link 1
13-98 - 3 defects found affecting 3 strips
13-98 - 1 maximum consecutive defects
13-98 - Cuts from: LS link 0
13-98 - Cuts from: LS link 1
13-115 - 1 defects found affecting 1 strips
13-115 - 1 maximum consecutive defects
13-115 - Cuts from: LS link 0
13-115 - Cuts from: LS link 1
13-132 - 2 defects found affecting 2 strips
13-132 - 1 maximum consecutive defects
13-132 - Cuts from: LS link 0
13-132 - Cuts from: LS link 1
13-149 - 4 defects found affecting 4 strips
13-149 - 1 maximum consecutive defects
13-149 - Cuts from: LS link 0
13-149 - Cuts from: LS link 1
13-166 - 3 defects found affecting 3 strips
13-166 - 1 maximum consecutive defects
13-166 - Cuts from: LS link 0
13-166 - Cuts from: LS link 1
13-183 - 4 defects found affecting 4 strips
13-183 - 1 maximum consecutive defects
13-183 - Cuts from: LS link 0
13-183 - Cuts from: LS link 1
13-200 - 2 defects found affecting 2 strips
13-200 - 1 maximum consecutive defects
13-200 - Cuts from: LS link 0
13-200 - Cuts from: LS link 1
13-217 - 6 defects found affecting 6 strips
13-217 - 1 maximum consecutive defects
13-217 - Cuts from: LS link 0
13-217 - Cuts from: LS link 1
13-234 - 2 defects found affecting 2 strips
13-234 - 1 maximum consecutive defects
13-234 - Cuts from: LS link 0
13-234 - Cuts from: LS link 1
13-251 - 3 defects found affecting 3 strips
13-251 - 1 maximum consecutive defects
13-251 - Cuts from: LS link 0
13-251 - Cuts from: LS link 1
13-268 - 4 defects found affecting 4 strips
13-268 - 1 maximum consecutive defects
13-268 - Cuts from: LS link 0
13-268 - Cuts from: LS link 1
13-285 - 3 defects found affecting 3 strips
13-285 - 1 maximum consecutive defects
13-285 - Cuts from: LS link 0
13-285 - Cuts from: LS link 1
13-302 - 2 defects found affecting 2 strips
13-302 - 1 maximum consecutive defects
13-302 - Cuts from: LS link 0
13-302 - Cuts from: LS link 1
13-319 - 3 defects found affecting 3 strips
13-319 - 1 maximum consecutive defects
13-319 - Cuts from: LS link 0
13-319 - Cuts from: LS link 1
13-336 - 4 defects found affecting 4 strips
13-336 - 1 maximum consecutive defects
13-336 - Cuts from: LS link 0
13-336 - Cuts from: LS link 1
13-353 - 3 defects found affecting 3 strips
13-353 - 1 maximum consecutive defects
13-353 - Cuts from: LS link 0
13-353 - Cuts from: LS link 1
13-370 - 3 defects found affecting 3 strips
13-370 - 1 maximum consecutive defects
13-370 - Cuts from: LS link 0
13-370 - Cuts from: LS link 1
13-388 - 4 defects found affecting 4 strips
13-388 - 1 maximum consecutive defects
13-388 - Cuts from: LS link 0
13-388 - Cuts from: LS link 1
13-404 - 4 defects found affecting 4 strips
13-404 - 1 maximum consecutive defects
13-404 - Cuts from: LS link 0
13-404 - Cuts from: LS link 1
13-421 - 2 defects found affecting 2 strips
13-421 - 1 maximum consecutive defects
13-421 - Cuts from: LS link 0
13-421 - Cuts from: LS link 1
Figures of gain and noise, and correlations with wafer/hybrid level test results, if they exist.
Thermal cycling results
Thermal cycling summaries will be given below
TCSvc::getListOfFilesFromDir INFO Scanning for test files 500-9492/20USBP05009492
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files 500-9492/20USBP05009492
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files GPC2328_X_014_B_H4/20USBHX2002922
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files GPC2328_X_014_B_H4/20USBHX2002922
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_RESPONSE_CURVE_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_PEDESTAL_TRIM_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_3PG_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_OPEN_CHANNEL_SEARCH_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_STROBE_DELAY_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBHX2002922_20250721_13_NO_TC.json
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files VPA38893-W02341/20USBSL0002341
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files VPA38893-W02341/20USBSL0002341
TCSvc::read INFO Found 0 results files...
TCSvc::getListOfFilesFromDir INFO Scanning for test files SCIPP-PS_LS-0119/20USBML1236246
TCSvc::getListOfJsonFilesFromDir INFO Scanning for test files SCIPP-PS_LS-0119/20USBML1236246
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_20250721_13_MODULE_IV_AMAC_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_20250721_13_MODULE_TC.json
TCSvc::getListOfJsonFilesFromDir INFO Loading json fle SN20USBML1236246_TESTED_20250722_13_432_HVSTABILITY.json
TCSvc::read INFO Found 0 results files...
IService::UPLOADDB INFO Working on test code PEDESTAL_TRIM_TC
IService::UPLOADDB INFO Working on test code STROBE_DELAY_TC
IService::UPLOADDB INFO Working on test code RESPONSE_CURVE_TC
IService::UPLOADDB INFO Working on test code NO_TC
IService::UPLOADDB INFO Working on test code MODULE_IV_AMAC_TC
IService::UPLOADDB INFO Working on test code HVSTABILITY
IService::UPLOADDB INFO Working on test code OPEN_CHANNEL_SEARCH_TC
IService::UPLOADDB INFO Working on test code MODULE_TC
IService::log INFO Logging status 0111 for component SCIPP-PS_LS-0119
IService::install INFO Installing output directory to /home/data/modules/SCIPP-PS_LS-0119/TCModules_PROD_v0-2/
IService::install INFO Installed warningLog.txt...
IService::install INFO Installed errorLog.txt...
IService::install INFO Installed infoLog.txt...
IService::install INFO Installed 20USBHX2002922_TC_Noise.pdf...
IService::install INFO Installed 20USBHX2002922_TC_Averages_RC_innse.pdf...
IService::install INFO Installed 20USBHX2002922_TC_Averages_RC_gain.pdf...
IService::install INFO Installed 20USBML1236246_TC_AMAC_IV_fast.pdf...
IService::install INFO Installed 20USBML1236246_TC_AMAC_IV.pdf...
IService::install INFO Installed 20USBML1236246_TC_ENV_DATA.pdf...
IService::install INFO Installed 20USBML1236246_TC_HV_STABILITY.pdf...
IService::install INFO Installed DB_READY_PEDESTAL_TRIM_TC_SN20USBHX2002922_20250721_13_PEDESTAL_TRIM_TC.json...
IService::install INFO Installed DB_READY_STROBE_DELAY_TC_SN20USBHX2002922_20250721_13_STROBE_DELAY_TC.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_TC_SN20USBHX2002922_20250721_13_RESPONSE_CURVE_TC.json...
IService::install INFO Installed DB_READY_RESPONSE_CURVE_TC_SN20USBHX2002922_20250721_13_3PG_TC.json...
IService::install INFO Installed DB_READY_NO_TC_SN20USBHX2002922_20250721_13_NO_TC.json...
IService::install INFO Installed DB_READY_MODULE_IV_AMAC_TC_SN20USBML1236246_20250721_13_MODULE_IV_AMAC_TC.json...
IService::install INFO Installed DB_READY_HVSTABILITY_SN20USBML1236246_TESTED_20250722_13_432_HVSTABILITY.json...
IService::install INFO Installed DB_READY_OPEN_CHANNEL_SEARCH_TC_SN20USBHX2002922_20250721_13_OPEN_CHANNEL_SEARCH_TC.json...
IService::install INFO Installed DB_READY_MODULE_TC_SN20USBML1236246_20250721_13_MODULE_TC.json...
IService::install INFO Installed SCIPP-PS_LS-0119.root...
IService::install INFO Installed status.json...
MetaData::readField INFO Reading file /home/data/upload//TCModules_PROD_v0//SCIPP-PS_LS-0122-2.config
IService::next INFO Scheduling SCIPP_PS_LS_0119_0120_0121_0122_TC file to run...
IService::next INFO Writing results to /home/data/output//TCModules_PROD_v0//SCIPP-PS_LS-0122/2/
✘ Component is at BNL. Prohibiting upload!
✘ Component fails stage checks. Current stage is ON_CORE but requires one of { "BONDED", "TESTED" }. Prohibiting upload!
Metadata
Value
Date
2025-07-21T12:48:14.000Z
Duration [hrs]
18.000
Max Humidity [%]
0.000
Max Temperature [C]
21.177
Min Temperature [C]
-35.051
Test Station
SCIPP_COLDBOX1
ITSDAQ Version
itsdaq_23_3_2023-2330-g8b9a82db6
User
qbl
Test Summary
Test
Passed
Problems
Open Channel Search
True
False
Pedestal Trim
True
False
Strobe Delay
True
False
3PG
True
False
Response Curve
True
False
Noise Occupancy
True
False
AMAC IV
True
False
HV Stability
True
False
Module TC
True
False
Response Curve Defect Summary
Defect #
Description
Chip Bank
Run Number
Chip #
Channel(s)
1
13-10
Strip with high gain
away
9
1279
2
13-10
Strip with high gain
under
3
385
3
13-10
Strip with high gain
under
9
1279
4
13-115
Strip with high noise
away
0
0
5
13-132
Strip with high gain
away
9
1279
6
13-132
Strip with high gain
under
9
1279
7
13-149
Strip with high noise
away
6
812
8
13-149
Strip with high gain
away
9
1279
9
13-149
Strip with high gain
under
3
385
10
13-149
Strip with high noise
under
9
1165
11
13-166
Strip with high gain
away
9
1279
12
13-166
Strip with high gain
under
3
385
13
13-166
Strip with high gain
under
9
1279
14
13-183
Strip with high noise
away
0
0
15
13-183
Strip with high noise
away
4
558
16
13-183
Strip with high gain
away
9
1279
17
13-183
Strip with high noise
under
1
230
18
13-200
Strip with high gain
away
9
1279
19
13-200
Strip with high gain
under
9
1279
20
13-217
Strip with high noise
away
0
0
21
13-217
Strip with high gain
away
9
1279
22
13-217
Strip with high noise
under
1
230
23
13-217
Strip with high gain
under
3
385
24
13-217
Strip with high noise
under
3
438
25
13-217
Strip with high noise
under
9
1165
26
13-234
Strip with high gain
away
9
1279
27
13-234
Strip with high gain
under
9
1279
28
13-251
Strip with high noise
away
0
0
29
13-251
Strip with high gain
away
9
1279
30
13-251
Strip with high noise
under
9
1165
31
13-268
Strip with high noise
away
0
0
32
13-268
Strip with high gain
away
9
1279
33
13-268
Strip with high gain
under
3
385
34
13-268
Strip with high gain
under
9
1279
35
13-285
Strip with high noise
away
4
574
36
13-285
Strip with high gain
away
9
1279
37
13-285
Strip with high noise
under
5
643
38
13-302
Strip with high gain
away
9
1279
39
13-302
Strip with high gain
under
9
1279
40
13-31
Strip with high noise
away
0
0
41
13-31
Strip with high gain
away
9
1279
42
13-319
Strip with high noise
away
0
0
43
13-319
Strip with high gain
away
9
1279
44
13-319
Strip with high gain
under
3
385
45
13-336
Strip with high noise
away
0
0
46
13-336
Strip with high gain
away
9
1279
47
13-336
Strip with high noise
under
5
640
48
13-336
Strip with high gain
under
9
1279
49
13-353
Strip with high gain
away
9
1279
50
13-353
Strip with high gain
under
3
385
51
13-353
Strip with high noise
under
9
1165
52
13-370
Strip with high gain
away
9
1279
53
13-370
Strip with high gain
under
3
385
54
13-370
Strip with high gain
under
9
1279
55
13-388
Strip with high noise
away
0
0
56
13-388
Strip with high noise
away
1
181
57
13-388
Strip with high noise
away
4
574
58
13-388
Strip with high gain
away
9
1279
59
13-404
Strip with high noise
away
0
0
60
13-404
Strip with high noise
away
4
574
61
13-404
Strip with high gain
away
9
1279
62
13-404
Strip with high noise
under
9
1165
63
13-421
Strip with high gain
away
9
1279
64
13-421
Strip with high gain
under
9
1279
65
13-47
Strip with high noise
away
0
0
66
13-47
Strip with high noise
away
1
142
67
13-47
Strip with high noise
away
4
574
68
13-47
Strip with high gain
away
9
1279
69
13-47
Strip with high noise
under
8
1079
70
13-64
Strip with high noise
away
5
640
71
13-64
Strip with high gain
away
9
1279
72
13-64
Strip with high gain
under
9
1279
73
13-81
Strip with high noise
away
0
0
74
13-81
Strip with high noise
away
4
538
75
13-81
Strip with high noise
away
4
574
76
13-81
Strip with high gain
away
9
1279
77
13-81
Strip with high noise
under
9
1165
78
13-98
Strip with high noise
away
0
0
79
13-98
Strip with high gain
away
9
1279
80
13-98
Strip with high gain
under
9
1279
Comments
Comments
13-10 - 3 defects found affecting 3 strips
13-10 - 1 maximum consecutive defects
13-10 - Cuts from: LS link 0
13-10 - Cuts from: LS link 1
13-31 - 2 defects found affecting 2 strips
13-31 - 1 maximum consecutive defects
13-31 - Cuts from: LS link 0
13-31 - Cuts from: LS link 1
13-47 - 5 defects found affecting 5 strips
13-47 - 1 maximum consecutive defects
13-47 - Cuts from: LS link 0
13-47 - Cuts from: LS link 1
13-64 - 3 defects found affecting 3 strips
13-64 - 1 maximum consecutive defects
13-64 - Cuts from: LS link 0
13-64 - Cuts from: LS link 1
13-81 - 5 defects found affecting 5 strips
13-81 - 1 maximum consecutive defects
13-81 - Cuts from: LS link 0
13-81 - Cuts from: LS link 1
13-98 - 3 defects found affecting 3 strips
13-98 - 1 maximum consecutive defects
13-98 - Cuts from: LS link 0
13-98 - Cuts from: LS link 1
13-115 - 1 defects found affecting 1 strips
13-115 - 1 maximum consecutive defects
13-115 - Cuts from: LS link 0
13-115 - Cuts from: LS link 1
13-132 - 2 defects found affecting 2 strips
13-132 - 1 maximum consecutive defects
13-132 - Cuts from: LS link 0
13-132 - Cuts from: LS link 1
13-149 - 4 defects found affecting 4 strips
13-149 - 1 maximum consecutive defects
13-149 - Cuts from: LS link 0
13-149 - Cuts from: LS link 1
13-166 - 3 defects found affecting 3 strips
13-166 - 1 maximum consecutive defects
13-166 - Cuts from: LS link 0
13-166 - Cuts from: LS link 1
13-183 - 4 defects found affecting 4 strips
13-183 - 1 maximum consecutive defects
13-183 - Cuts from: LS link 0
13-183 - Cuts from: LS link 1
13-200 - 2 defects found affecting 2 strips
13-200 - 1 maximum consecutive defects
13-200 - Cuts from: LS link 0
13-200 - Cuts from: LS link 1
13-217 - 6 defects found affecting 6 strips
13-217 - 1 maximum consecutive defects
13-217 - Cuts from: LS link 0
13-217 - Cuts from: LS link 1
13-234 - 2 defects found affecting 2 strips
13-234 - 1 maximum consecutive defects
13-234 - Cuts from: LS link 0
13-234 - Cuts from: LS link 1
13-251 - 3 defects found affecting 3 strips
13-251 - 1 maximum consecutive defects
13-251 - Cuts from: LS link 0
13-251 - Cuts from: LS link 1
13-268 - 4 defects found affecting 4 strips
13-268 - 1 maximum consecutive defects
13-268 - Cuts from: LS link 0
13-268 - Cuts from: LS link 1
13-285 - 3 defects found affecting 3 strips
13-285 - 1 maximum consecutive defects
13-285 - Cuts from: LS link 0
13-285 - Cuts from: LS link 1
13-302 - 2 defects found affecting 2 strips
13-302 - 1 maximum consecutive defects
13-302 - Cuts from: LS link 0
13-302 - Cuts from: LS link 1
13-319 - 3 defects found affecting 3 strips
13-319 - 1 maximum consecutive defects
13-319 - Cuts from: LS link 0
13-319 - Cuts from: LS link 1
13-336 - 4 defects found affecting 4 strips
13-336 - 1 maximum consecutive defects
13-336 - Cuts from: LS link 0
13-336 - Cuts from: LS link 1
13-353 - 3 defects found affecting 3 strips
13-353 - 1 maximum consecutive defects
13-353 - Cuts from: LS link 0
13-353 - Cuts from: LS link 1
13-370 - 3 defects found affecting 3 strips
13-370 - 1 maximum consecutive defects
13-370 - Cuts from: LS link 0
13-370 - Cuts from: LS link 1
13-388 - 4 defects found affecting 4 strips
13-388 - 1 maximum consecutive defects
13-388 - Cuts from: LS link 0
13-388 - Cuts from: LS link 1
13-404 - 4 defects found affecting 4 strips
13-404 - 1 maximum consecutive defects
13-404 - Cuts from: LS link 0
13-404 - Cuts from: LS link 1
13-421 - 2 defects found affecting 2 strips
13-421 - 1 maximum consecutive defects
13-421 - Cuts from: LS link 0
13-421 - Cuts from: LS link 1